文献速递结核与非结核分枝杆菌

胸部X线计算机辅助检测软件在家庭接触者中检测现患和突发结核病的诊断准确性

Diagnostic Accuracy of Chest X-ray Computer-Aided Detection Software for Detection of Prevalent and Incident Tuberculosis in Household Contacts.
PubMed 文献 · Clin Infect Dis · 2025-01-01

本研究在南非对利福平耐药结核病家庭接触者进行前瞻性队列研究,随访4.6年,评估三种胸部X线计算机辅助检测软件(CAD4TBv7.0、qXRv3.0.0、Lunit INSIGHT v3.1.4.111)检测现患和突发结核病的诊断准确性。结果显示,检测现患结核病的AUC ROC为.87至.91,超过30%的CAD评分高于推荐阈值但常规痰检阴性的参与者随后被诊断为结核病,CAD对现患结核病的诊断性能优于血液检测。

要点

  • 三种CAD软件检测现患结核病的AUC ROC为.87至.91。
  • 超过30%的CAD评分高于阈值但常规痰检阴性者随后诊断为结核病。
  • CAD检测突发结核病的AUC为.60至.65。

核心结论

  • 研究发现,CAD-CXR筛查结核病的潜力未被最大化,因为高比例CAD评分高于当前阈值但常规确认痰检阴性的个体具有真正的结核病,可能从干预中获益。

研究设计与样本

  • 在南非进行的前瞻性队列研究,纳入利福平耐药结核病家庭接触者,基线进行胸部X线检查和痰检(常规单次自咳痰和增强额外2-3次诱导痰),随访突发结核病,比较三种CAD软件(CAD4TBv7.0、qXRv3.0.0、Lunit INSIGHT v3.1.4.111)的性能,并在亚组中与血液检测(Xpert MTB宿主反应、红细胞沉降率、C反应蛋白、QuantiFERON)比较。

主要发现

  • 483名参与者随访4.6年(中位数),现患结核病23例(其中常规诊断7例),突发结核病38例。
  • CAD4TBv7.0、qXRv3.0.0和Lunit INSIGHT v3.1.4.111检测现患结核病的AUC ROC(95%CI)分别为.87(.77-.96)、.88(.79-.97)和.91(.83-.99)。
  • 超过30%的CAD评分高于推荐阈值但常规基线痰检细菌学阴性的参与者随后通过增强痰检或随访被诊断。
  • 基线CAD检测突发结核病的AUC性能范围为.60至.65。
  • CAD对现患结核病的诊断性能优于血液检测。

关键数值与推荐

  • 世界卫生组织结核病筛查指南推荐使用计算机辅助检测软件进行胸部X线片解读。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: World Health Organization (WHO) tuberculosis (TB) screening guidelines recommend computer-aided detection (CAD) software for chest radiograph (CXR) interpretation. However, studies evaluating their diagnostic and prognostic accuracy are limited. METHODS: We conducted a prospective cohort study of household contacts of rifampicin-resistant TB in South Africa. Participants underwent baseline CXR and sputum investigation (routine [single spontaneous] and enhanced [additionally 2-3 induced]) for prevalent TB and follow-up for incident TB. Three CXR-CAD software products (CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111) were compared. We evaluated their performance to detect routine and enhanced prevalent and incident TB, comparing performance with blood tests (Xpert MTB host-response, erythrocyte sedimentation rate, C-reactive protein, QuantiFERON) in a subgroup. RESULTS: 483 participants were followed up for 4.6 years (median). There were 23 prevalent (7 routinely diagnosed) and 38 incident TB cases. The AUC ROCs (95% CIs) to identify prevalent TB for CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111 were .87 (.77-.96), .88 (.79-.97), and .91 (.83-.99), respectively. More than 30% with scores above recommended CAD thresholds who were bacteriologically negative on routine baseline sputum were subsequently diagnosed by enhanced sputum investigation or during follow-up. The AUC performance of baseline CAD to identify incident cases ranged between .60 and .65. Diagnostic performance of CAD for prevalent TB was superior to blood testing. CONCLUSIONS: Our findings suggest that the potential of CAD-CXR screening for TB is not maximized as a high proportion of those above current thresholds, but with a negative routine confirmatory sputum, have true TB disease that may benefit intervention.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Macpherson L, Kik SV, Quartagno M, et al. Diagnostic Accuracy of Chest X-ray Computer-Aided Detection Software for Detection of Prevalent and Incident Tuberculosis in Household Contacts. Clin Infect Dis. 2025. PMID: 39692469. doi:10.1093/cid/ciae528

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。