前瞻性多国队列中结核筛查试验的诊断准确性:计算机辅助检测胸片、Xpert结核宿主反应与C反应蛋白

Diagnostic Accuracy of Tuberculosis Screening Tests in a Prospective Multinational Cohort: Chest Radiography With Computer-Aided Detection, Xpert Tuberculosis Host Response, and C-Reactive Protein.
PubMed 文献 · Clin Infect Dis · 2026-01-01

研究在菲律宾、越南、南非、乌干达和印度基层卫生中心前瞻性筛查≥2周咳嗽的成人,评估CAD4TB v7、Xpert HR和CRP对结核的诊断准确性。在1392例中303例(22%)确诊结核;CAD4TB v7在90%灵敏度下特异度最高(70.3%),优于Xpert HR(65.1%)和CRP(49.7%)。三种两试验筛查算法达到世界卫生组织目标产品概况最低准确性阈值,且准确性高于任一单项试验。

要点

  • CAD4TB v7在90%灵敏度下特异度70.3%,高于Xpert HR的65.1%和CRP的49.7%。
  • 三种两试验筛查算法达到WHO目标产品概况最低准确性阈值,准确性高于任一单项试验。
  • 90%灵敏度下,Xpert HR-CAD4TB序贯阴性算法特异度79.6%,CRP-CAD4TB序贯阴性75.9%,Xpert HR-CAD4TB序贯阳性73.7%。

核心结论

  • CAD4TB v7达到目标产品概况目标,并优于Xpert HR和CRP;联合筛查试验进一步提高准确性。

研究设计与样本

  • 前瞻性多国队列,在菲律宾、越南、南非、乌干达和印度基层卫生中心筛查≥2周咳嗽的成人。
  • 参与者接受胸片、Cepheid Xpert TB Host Response(Xpert HR)检测和即时C反应蛋白(CRP)检测(Boditech)。
  • 胸片使用计算机辅助检测算法CAD4TB v7处理,以微生物学参考标准(痰Xpert Ultra、培养)评估诊断准确性。
  • 最佳截断点选择为在90%灵敏度下最大化特异度;考虑两种两试验筛查算法:序贯阴性串联筛查(任一试验阳性即阳性)和序贯阳性串联筛查(两试验均阳性才阳性)。
  • 2021年7月至2022年8月,共1392例疑似结核参与者有有效指标试验和参考标准结果,303例(22%)确诊结核。

主要发现

  • 在头对头比较中,CAD4TB v7在90%灵敏度下特异度最高:70.3% vs Xpert HR 65.1%(特异度绝对差异95%CI 1.6%-8.9%),vs CRP 49.7%(95%CI 17.0%-24.3%)。
  • 三种两试验筛查算法达到世界卫生组织目标产品概况最低准确性阈值,且准确性高于任一单项试验。
  • 在90%灵敏度下,Xpert HR-CAD4TB序贯阴性算法特异度为79.6%,CRP-CAD4TB序贯阴性算法为75.9%,Xpert HR-CAD4TB序贯阳性算法为73.7%。

关键数值与推荐

  • CAD4TB v7在90%灵敏度下特异度70.3%,Xpert HR为65.1%,CRP为49.7%。
  • Xpert HR-CAD4TB序贯阴性算法在90%灵敏度下特异度79.6%。
  • CRP-CAD4TB序贯阴性算法在90%灵敏度下特异度75.9%。
  • Xpert HR-CAD4TB序贯阳性算法在90%灵敏度下特异度73.7%。

临床怎么用

  • CAD4TB v7达到目标产品概况目标并优于Xpert HR和CRP,联合筛查试验可进一步提高准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Accessible, accurate screening tests are necessary to advance tuberculosis case finding and early detection in high-burden countries. METHODS: We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants underwent chest radiography, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest radiographs were processed using CAD4TB v7, a computer-aided detection (CAD) algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cutoff points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using (1) sequential negative serial screening (with positive defined as positive on either test) and (2) sequential positive serial screening (with positive defined as positive on both tests). RESULTS: Between July 2021 and August 2022, a total of 1392 participants with presumptive tuberculosis had valid index tests and reference standard results, and 303 (22%) had confirmed tuberculosis. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs 65.1% for Xpert HR [95% confidence interval for absolute difference in specificity, 1.6%-8.9%] and vs 49.7% for CRP [17.0%-24.3%]). Three 2-test screening algorithms met World Health Organization target product profile minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB (sequential negative), 75.9% for CRP-CAD4TB (sequential negative), and 73.7% for Xpert HR-CAD4TB (sequential positive). CONCLUSIONS: CAD4TB achieves target product profile targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Clinical Trials Registration. NCT04923958.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Crowder R, Thangakunam B, Andama A, et al. Diagnostic Accuracy of Tuberculosis Screening Tests in a Prospective Multinational Cohort: Chest Radiography With Computer-Aided Detection, Xpert Tuberculosis Host Response, and C-Reactive Protein. Clin Infect Dis. 2026. PMID: 39509711. doi:10.1093/cid/ciae549