文献速递结核与非结核分枝杆菌艾滋病与性传播感染

评估C反应蛋白与计算机辅助分析胸部X线作为莱索托和南非医疗机构结核病分诊试验

Evaluation of C-Reactive Protein and Computer-Aided Analysis of Chest X-rays as Tuberculosis Triage Tests at Health Facilities in Lesotho and South Africa.
PubMed 文献 · Clin Infect Dis · 2024-01-01

研究前瞻性纳入1392名有结核症状的成人,在莱索托和南非的医疗机构中比较CAD4TBv7软件与C反应蛋白(CRP)作为结核病分诊试验的表现。CAD4TBv7的曲线下面积为0.87,在90%灵敏度下特异度为68.2%;CRP的曲线下面积为0.80,在90%灵敏度下特异度为38.2%。CAD4TBv7几乎达到世界卫生组织分诊试验目标产品规范,CRP在结核病分诊中的作用需进一步研究。

要点

  • CAD4TBv7在90%灵敏度下特异度为68.2%,接近WHO分诊试验目标(灵敏度>90%,特异度>70%)。
  • CRP在90%灵敏度下特异度为38.2%,其分诊价值需进一步研究。
  • CAD4TBv7检测结核病的能力与专家放射科医生相当。

核心结论

  • CAD4TBv7作为来自结核病和HIV高负担地区有结核症状患者的分诊试验是准确的,几乎达到WHO分诊试验目标产品规范。
  • CRP在结核病分诊中的作用需要进一步研究。

研究设计与样本

  • 前瞻性研究,在莱索托和南非的医疗机构连续招募年龄≥18岁、出现4种主要结核症状中至少1种的成人,招募时间为2021年2月至2022年4月。
  • 每位参与者接受数字胸部X线用于CAD4TBv7分析和CRP检测,并提供1份痰标本用于Xpert MTB/RIF Ultra和Xpert MTB/RIF检测及1份用于液体培养;另由专家放射科医生通过远程放射学阅读胸片。
  • 主要分析采用复合微生物学参考标准(即培养阳性或Xpert Ultra阳性)。

主要发现

  • 共纳入1392名参与者,其中48%为HIV感染者,24%有既往结核病史。
  • CAD4TBv7和CRP的受试者工作特征曲线下面积分别为0.87(95%CI:0.84-0.91)和0.80(95%CI:0.76-0.84)。
  • 在对应90%灵敏度的阈值下,CAD4TBv7的特异度为68.2%(95%CI:65.4-71.0%),CRP的特异度为38.2%(95%CI:35.3-41.1%)。
  • CAD4TBv7检测结核病的能力与专家放射科医生相当。

局限性

  • CRP在结核病分诊中的作用需要进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To improve tuberculosis case-finding, rapid, non-sputum triage tests need to be developed according to the World Health Organization target product profile (TPP) (>90% sensitivity, >70% specificity). We prospectively evaluated and compared artificial intelligence-based, computer-aided detection software, CAD4TBv7, and C-reactive protein assay (CRP) as triage tests at health facilities in Lesotho and South Africa. METHODS: Adults (≥18 years) presenting with ≥1 of the 4 cardinal tuberculosis symptoms were consecutively recruited between February 2021 and April 2022. After informed consent, each participant underwent a digital chest X-ray for CAD4TBv7 and a CRP test. Participants provided 1 sputum sample for Xpert MTB/RIF Ultra and Xpert MTB/RIF and 1 for liquid culture. Additionally, an expert radiologist read the chest X-rays via teleradiology. For primary analysis, a composite microbiological reference standard (ie, positive culture or Xpert Ultra) was used. RESULTS: We enrolled 1392 participants, 48% were people with HIV and 24% had previously tuberculosis. The receiver operating characteristic curve for CAD4TBv7 and CRP showed an area under the curve of .87 (95% CI: .84-.91) and .80 (95% CI: .76-.84), respectively. At thresholds corresponding to 90% sensitivity, specificity was 68.2% (95% CI: 65.4-71.0%) and 38.2% (95% CI: 35.3-41.1%) for CAD4TBv7 and CRP, respectively. CAD4TBv7 detected tuberculosis as well as an expert radiologist. CAD4TBv7 almost met the TPP criteria for tuberculosis triage. CONCLUSIONS: CAD4TBv7 is accurate as a triage test for patients with tuberculosis symptoms from areas with a high tuberculosis and HIV burden. The role of CRP in tuberculosis triage requires further research. CLINICAL TRIALS REGISTRATION: Clinicaltrials.gov identifier: NCT04666311.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Bosman S, Ayakaka I, Muhairwe J, et al. Evaluation of C-Reactive Protein and Computer-Aided Analysis of Chest X-rays as Tuberculosis Triage Tests at Health Facilities in Lesotho and South Africa. Clin Infect Dis. 2024. PMID: 39190813. doi:10.1093/cid/ciae378

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。