这项多中心队列研究在中国6省9个中心连续纳入321例疑似结核性胸膜炎患者(≥5岁),最终281例数据可用,其中确诊105例、可能113例、非结核63例。cf-ddPCR在确诊组灵敏度90.5%,显著高于培养法57.1%、Xpert 46.7%、Ultra 69.5%和实时PCR 75.2%;在可能组灵敏度61.1%,仍显著高于Ultra 27.4%和实时PCR 38.9%。

要点

  • cf-ddPCR在确诊结核性胸膜炎组灵敏度90.5%,显著高于培养法、Xpert、Ultra和实时PCR。
  • 在培养和Xpert均阴性的可能结核性胸膜炎组,cf-ddPCR灵敏度61.1%,仍显著高于Ultra和实时PCR。
  • 作者认为cf-ddPCR性能优于培养法、Xpert、Ultra和实时PCR,可预期提高诊断准确性。

核心结论

  • cf-ddPCR的诊断性能优于培养法、Xpert、Ultra和实时PCR,作者认为采用该新检测可预期提高诊断准确性。

研究设计与样本

  • 多中心队列研究,2020年9月至2022年5月在中国6省9个研究中心连续纳入≥5岁疑似结核性胸膜炎且伴胸腔积液的患者。
  • 所有标本同时进行培养法、Xpert、Xpert MTB/RIF Ultra、实时PCR和cf-ddPCR检测。
  • 共纳入321例参与者,281例(87.5%)数据可用,按复合参考标准分为确诊结核性胸膜炎105例、可能结核性胸膜炎113例和非结核性胸膜炎63例。

主要发现

  • 确诊结核性胸膜炎组cf-ddPCR灵敏度90.5%(95/105,95%CI 82.8-95.1%),显著高于培养法57.1%(60/105,95%CI 47.1-66.6%,p<0.001)。
  • 确诊结核性胸膜炎组cf-ddPCR灵敏度显著高于Xpert 46.7%(49/105,95%CI 37.0-56.6%,p<0.001)、Ultra 69.5%(73/105,95%CI 59.7-77.9%,p<0.001)和实时PCR 75.2%(79/105,95%CI 65.7-82.9%,p<0.001)。
  • 在培养法和Xpert均阴性的可能结核性胸膜炎组,cf-ddPCR灵敏度61.1%(69/113,95%CI 51.4-70.0%),显著高于Ultra 27.4%(31/113,95%CI 19.7-36.8%,p<0.001)和实时PCR 38.9%(44/113,95%CI 30.0-48.6%,p<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Tuberculous pleurisy is one of the most common types of extra-pulmonary tuberculosis, but the sensitivity of conventional mycobacterial culture (Culture) or Xpert MTB/RIF assay (Xpert) is not satisfying. This multicentre cohort study evaluated the accuracy of a new cell-free DNA droplet digital PCR assay (cf-ddPCR) for diagnosing tuberculous pleurisy. METHODS: Patients with suspected tuberculosis (≥5 years of age) with pleural effusion were consecutively recruited from nine research sites across six provinces in China between September 2020 to May 2022. Culture, Xpert, Xpert MTB/RIF Ultra assay (Ultra), real-time PCR, and cf-ddPCR were performed simultaneously for all specimens. RESULTS: A total of 321 participants were enrolled, and data from 281 (87.5%) participants were available, including 105 definite tuberculous pleurisy, 113 possible tuberculous pleurisy and 63 non-tuberculous pleurisy according to the composite reference standard. The sensitivity of cf-ddPCR was 90.5% (95/105, 95% CI, 82.8-95.1%) in the definite tuberculous pleurisy group, which was significantly higher than those of Culture (57.1%, 60/105, 95% CI, 47.1-66.6%, p < 0.001), Xpert (46.7%, 49/105, 95% CI, 37.0-56.6%, p < 0.001), Ultra (69.5%, 73/105, 95% CI, 59.7-77.9%, p < 0.001) and real-time PCR (75.2%, 79/105, 95% CI, 65.7-82.9%, p < 0.001). In possible tuberculous pleurisy, whose results of Culture and Xpert were both negative, the sensitivity of cf-ddPCR was 61.1% (69/113, 95% CI, 51.4-70.0%), which was still significantly higher than that of Ultra (27.4%, 31/113, 95% CI, 19.7-36.8%, p < 0.001) and real-time PCR (38.9%, 44/113, 95% CI, 30.0-48.6%, p < 0.001). DISCUSSION: The performance of cf-ddPCR is superior to Culture, Xpert, Ultra, and real-time PCR, indicating that improved diagnostic accuracy can be anticipated by incorporating this new assay.