文献速递细菌感染、耐药与抗菌药物医院感染防控

脉冲氙紫外线降低多重耐药菌获得(LAMP)研究:一项整群随机、对照、双盲、干预性交叉试验

Lowering the Acquisition of Multidrug-Resistant Organisms (MDROs) With Pulsed-xenon (LAMP) Study: A Cluster-Randomized, Controlled, Double-Blinded, Interventional Crossover Trial.
PubMed 文献 · Clin Infect Dis · 2024-01-01

LAMP试验在2家医院15个住院病房开展整群随机、对照、双盲、干预性交叉试验,比较标准终末清洁后加脉冲氙紫外线(PX-UV)与假消毒对环境中涉及医疗相关感染(eiHAIs)的影响。2017年5月18日至2020年1月7日纳入25 732例患者,eiHAIs发生率干预组与假消毒组分别为3.49 vs 3.17例/1000患者日(RR 1.10;95%CI 0.94-1.29;P=0.23),无差异。结论:加用紫外线消毒未能降低eiHAIs发生率。

要点

  • 标准终末清洁后加PX-UV与假消毒相比,eiHAIs发生率无差异(3.49 vs 3.17例/1000患者日;RR 1.10;95%CI 0.94-1.29;P=0.23)。
  • 按eiHAI类型、医院和病房类型分层后结果相似。
  • 作者认为需进一步研究针对医院环境表面和无接触技术降低医疗相关感染的作用。

核心结论

  • LAMP研究未能证明标准终末清洁后加用紫外线消毒可降低eiHAIs发生率。

研究设计与样本

  • 在2家医院15个住院病房开展的整群随机、对照、双盲、干预性交叉试验,比较标准终末清洁后加PX-UV(干预组)与假消毒(对照组)。
  • 主要结局为住院第4天或之后、或离开研究病房后3天内临床微生物检测诊断的eiHAIs发生率。
  • eiHAIs包括耐万古霉素肠球菌、产超广谱β-内酰胺酶大肠埃希菌或肺炎克雷伯菌、耐甲氧西林金黄色葡萄球菌和鲍曼不动杆菌临床培养阳性,以及艰难梭菌粪便PCR阳性。
  • 2017年5月18日至2020年1月7日共纳入25 732例患者,eiHAIs 601例次,患者日180 954。

主要发现

  • 干预组与假消毒组eiHAIs发生率分别为3.49 vs 3.17例/1000患者日(RR 1.10;95%CI 0.94-1.29;P=0.23),无差异。
  • 按eiHAI类型、医院和病房类型分层后结果相似。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需进一步研究针对医院环境表面和无接触技术降低医疗相关感染的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Environmental disinfection is essential for reducing spread of healthcare-associated infections (HAIs). Previous studies report conflicting results regarding the effects of ultraviolet (UV) light in reducing infections. This trial evaluated the impact of adding pulsed-xenon UV (PX-UV) to standard terminal cleaning in reducing environmentally implicated HAIs (eiHAIs). METHODS: The Lowering the Acquisition of MDROs with Pulsed-xenon (LAMP) trial was conducted in 2 hospitals (15 inpatient wards) utilizing a cluster-randomized, controlled, double-blinded, interventional crossover trial comparing standard terminal cleaning followed by either PX-UV (intervention arm) or sham (control arm) disinfection. The primary outcome was incidence of eiHAIs from clinical microbiology tests on the fourth day of stay or later or within 3 days after discharge from the study unit. EiHAIs included clinical cultures positive for vancomycin-resistant enterococci, extended-spectrum beta-lactamase-producing Escherichia coli or Klebsiella pneumonia, methicillin-resistant Staphylococcus aureus, and Acinetobacter baumannii, and stool polymerase chain reaction (PCR) positive for Clostridiodes difficile. RESULTS: Between 18 May 2017 and 7 January 2020, 25 732 patients were included, with an incidence of 601 eiHAIs and 180 954 patient-days. There was no difference in the rate of eiHAIs in the intervention and sham arms (3.49 vs 3.17 infections/1000 patient-days, respectively; RR, 1.10; 95% CI, .94-1.29; P = .23). Study results were similar when stratified by eiHAI type, hospital, and unit type. CONCLUSIONS: The LAMP study failed to demonstrate an effect of the addition of UV light disinfection following terminal cleaning on reductions in rates of eiHAIs. Further investigations targeting hospital environmental surfaces and the role of no-touch technology to reduce HAIs are needed. Clinical Trials Registration. ClinicalTrials.gov identifier: NCT03349268; R01HS024709.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Dhar S, Jinadatha C, Kilgore PE, et al. Lowering the Acquisition of Multidrug-Resistant Organisms (MDROs) With Pulsed-xenon (LAMP) Study: A Cluster-Randomized, Controlled, Double-Blinded, Interventional Crossover Trial. Clin Infect Dis. 2024. PMID: 38743564. doi:10.1093/cid/ciae240