研究对澳大利亚育肥场牛源多杀性巴氏杆菌ST394参考基因组17BRD-035进行生物信息学分析,鉴定出新型整合性接合元件ICE-PmuST394,其携带blaROB-1、blaROB-13和estT,赋予氨苄西林和替米考星耐药但不赋予图拉霉素和替地匹罗星耐药。该元件通过克隆扩增和水平转移传播,目前局限于澳大利亚一个育肥场,作者建议定期监测其存在或扩散。

要点

  • ICE-PmuST394携带blaROB-1、blaROB-13和estT,介导氨苄西林和替米考星耐药,不介导图拉霉素和替地匹罗星耐药。
  • 该元件在澳大利亚另外3株分离株(2株ST394和1株ST125)中检出,可能存在于美国ST79基因组中。
  • ICE-PmuST394通过克隆扩增和水平转移传播,目前局限于澳大利亚一个育肥场,作者建议定期监测。

核心结论

  • ICE-PmuST394携带少量不寻常的抗菌药物耐药基因,但具有促进基因组重组的热点,因此易于容纳更多耐药基因,其存在或扩散应定期监测。
  • 该元件具有独特的分子标记,可用于本地和全球的基因组监测。

研究设计与样本

  • 对多杀性巴氏杆菌17BRD-035(ST394参考基因组)进行生物信息学分析,以确定携带耐药基因的整合性接合元件是否在澳大利亚育肥场中流行。

主要发现

  • 在17BRD-035中鉴定出新型元件ICE-PmuST394,并在澳大利亚另外3株分离株(2株ST394和1株ST125)中检出,可能存在于代表美国ST79的基因组中。
  • ICE-PmuST394含耐药模块,携带blaROB基因的两个变体blaROB-1和blaROB-13以及大环内酯酯酶基因estT。
  • 该耐药基因组合赋予对氨苄西林和替米考星的耐药性,但不赋予对图拉霉素和替地匹罗星的耐药性。
  • 分析提示ICE-PmuST394通过克隆扩增和水平转移传播,但目前局限于澳大利亚一个育肥场。

临床怎么用

  • 作者建议定期监测ICE-PmuST394的存在或扩散。
  • 作者指出该元件的独特分子标记可用于本地和全球的基因组监测。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The emergence of macrolide and tetracycline resistance within Pasteurella multocida isolated from feedlot cattle and the dominance of ST394 in Australia was reported recently. OBJECTIVES: To establish the genetic context of the resistance genes in P. multocida 17BRD-035, the ST394 reference genome, and conduct a molecular risk assessment of their ability to disperse laterally. METHODS: A bioinformatic analysis of the P. multocida 17BRD-035 genome was conducted to determine if integrative conjugative elements (ICEs) carrying resistance genes, which hamper antibiotic treatment options locally, are in circulation in Australian feedlots. RESULTS: A novel element, ICE-PmuST394, was characterized in P. multocida 17BRD-035. It was also identified in three other isolates (two ST394s and a ST125) in Australia and is likely present in a genome representing P. multocida ST79 from the USA. ICE-PmuST394 houses a resistance module carrying two variants of the blaROB gene, blaROB-1 and blaROB-13, and the macrolide esterase gene, estT. The resistance gene combination on ICE-PmuST394 confers resistance to ampicillin and tilmicosin, but not to tulathromycin and tildipirosin. Our analysis suggests that ICE-PmuST394 is circulating both by clonal expansion and horizontal transfer but is currently restricted to a single feedlot in Australia. CONCLUSIONS: ICE-PmuST394 carries a limited number of unusual antimicrobial resistance genes but has hotspots that facilitate genomic recombination. The element is therefore amenable to hosting more resistance genes, and therefore its presence (or dispersal) should be regularly monitored. The element has a unique molecular marker, which could be exploited for genomic surveillance purposes locally and globally.