文献速递细菌感染、耐药与抗菌药物

高通量机器人强化抗菌药物耐药性监测发现耐氟喹诺酮大肠埃希菌菌株跨国流入禽类

Augmented surveillance of antimicrobial resistance with high-throughput robotics detects transnational flow of fluoroquinolone-resistant Escherichia coli strain into poultry.
PubMed 文献 · J Antimicrob Chemother · 2023-01-01

研究对10群肉禽的295份盲肠样本用高通量机器人筛查,琼脂稀释法显示氨苄西林和四环素耐药普遍(平均携带5.8 log10 cfu/g),环丙沙星耐药株经全基因组测序提示跨国流入澳大利亚禽群。

要点

  • 高通量机器人可扩大食品动物耐药监测规模并早期发现新发耐药。
  • 氨苄西林和四环素耐药普遍,庆大霉素和环丙沙星耐药定植较少。
  • 全基因组测序提示环丙沙星耐药株跨国流入澳大利亚禽群。

核心结论

  • 常用耐药监测方法无法实现新发耐药的早期发现或测量时空耐药趋势。
  • 遗传分析提示环丙沙星耐药菌株跨国流入澳大利亚禽群,解释了在禁止禽类使用氟喹诺酮的国家检出该耐药株。

研究设计与样本

  • 从10群肉禽采集295份盲肠样本,用高通量机器人筛查。
  • 初筛采用琼脂稀释法(5310块板)定量各样本耐药携带量(cfu/g)。
  • 91株环丙沙星耐药分离株进行肉汤微量稀释药敏试验。
  • 28株环丙沙星耐药分离株进行全基因组测序和系统发育分析。

主要发现

  • 氨苄西林和四环素耐药在所有禽群多数禽中普遍存在,平均携带率为5.8 log10 cfu/g。
  • 庆大霉素耐药大肠埃希菌定植禽数较少,平均携带率为1.2 log10 cfu/g粪便。
  • 环丙沙星耐药大肠埃希菌定植禽数较少,平均携带率为1.0 log10 cfu/g粪便。
  • 未检出对超广谱头孢菌素耐药。
  • 全基因组测序分离株中ST354为优势序列型,但其耐药基因携带量明显低于国际同类菌株。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Food animal AMR surveillance programs assess only small numbers of Escherichia coli (from 100 to 600 per animal class) nationally each year, severely limiting the evaluation of public health risk(s). Here we demonstrate an affordable approach for early detection of emerging resistance on a broad scale that can also accurately characterize spatial and temporal changes in resistance. METHODS: Caecal samples (n = 295) obtained from 10 meat poultry were screened using high-throughput robotics. Initial screening via agar dilution (5310 plates) quantified AMR carriage (cfu/g) for each sample. Ciprofloxacin-resistant isolates (n = 91) proceeded to downstream broth microdilution susceptibility testing. A subset of 28 ciprofloxacin-resistant isolates underwent WGS and phylogenetic analysis. RESULTS: Intra- and inter-flock carriage of resistance varied with drug class. Ampicillin and tetracycline resistance was ubiquitous to most birds in all flocks with an average carriage rate of 5.8 log10 cfu/g. Gentamicin and ciprofloxacin-resistant E. coli colonized fewer birds, and had an average carriage rate of 1.2 log10 cfu/g and 1.0 log10 cfu/g of faeces, respectively. Resistance to extended-spectrum cephalosporins was absent. ST354 was the dominant ST among the WGS isolates, but they demonstrated markedly lower resistance gene carriage than their international counterparts. CONCLUSIONS: These data amply demonstrate the ineffectiveness of commonly relied-on approaches to AMR surveillance for achieving early detection of emergence, or for measuring spatial and temporal resistance trends. Genetic analysis suggested there has been transnational flow of a ciprofloxacin-resistant strain into Australian poultry flocks, explaining their detection in a nation that prohibits fluoroquinolone use in poultry.

来源:J Antimicrob Chemother,查看原文。版权归原作者所有。

引用

  1. Truswell A, Lee ZZ, Stegger M, et al. Augmented surveillance of antimicrobial resistance with high-throughput robotics detects transnational flow of fluoroquinolone-resistant Escherichia coli strain into poultry. J Antimicrob Chemother. 2023. PMID: 37864344. doi:10.1093/jac/dkad323