常规基质辅助激光解吸电离飞行时间质谱的脂质指纹图谱用于诊断结核分枝杆菌复合群菌种的表现
本研究采用盲法设计,以7株参考株建立脂质数据库,评估基于脂质的基质辅助激光解吸电离飞行时间质谱(MALDI-TOF)对90株结核分枝杆菌复合群(MTBC)临床分离株的菌种鉴定能力。该方法快速(<10分钟),86株获得可解读谱图;敏感度和特异度均为94.4%(95%CI分别为86.4-98.5和72.7-99.9)。结论认为分枝杆菌脂质谱可快速、安全、准确地区分MTBC内菌种。
要点
- 基于脂质的MALDI-TOF可在<10分钟内快速鉴定MTBC菌种。
- 90株临床分离株中86株获得可解读谱图,4株因离子化不佳未能解读。
- 敏感度和特异度均为94.4%(95%CI分别为86.4-98.5和72.7-99.9)。
核心结论
- 分枝杆菌脂质谱可快速、安全、准确地区分MTBC内的菌种。
研究设计与样本
- 盲法研究,使用90株分枝杆菌临床分离株(含MTBC菌株)和7株参考株(M. tuberculosis H37Rv、M canettii、M. africanum、M. pinnipedii、M. caprae、M. bovis、M. bovis BCG)建立参考脂质数据库。
- 临床分离株在Middlebrook 7H11培养基(补充10%油酸、葡萄糖、过氧化氢酶生长补充剂)中于37°C培养最多6周,参考株在相同条件下培养。
- 培养的分枝杆菌经热灭活后点靶,加基质,正离子模式采集数据。
主要发现
- 基于7株参考株的清晰脂质特征,所开发方法快速(<10分钟),除4株因离子化不佳外均产生可解读谱图,n=86获得可解读谱图。
- MALDI-TOF的敏感度为94.4%(95%CI,86.4-98.5),特异度为94.4%(95%CI,72.7-99.9)。
局限性
- 90株临床分离株中4株因离子化不佳未能获得可解读谱图(n=86获得可解读谱图)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Rapid detection of bacterial pathogens at species and sub-species levels is crucial for appropriate treatment, infection control, and public health management. Currently, one of the challenges in clinical microbiology is the discrimination of mycobacterial sub-species within the M. tuberculosis complex (MTBC). Our objective was to evaluate the ability of a biosafe mycobacterial lipid-based approach to identify MTBC cultures and sub-species. METHODS: A blinded study was conducted using 90 mycobacterial clinical isolate strains comprising MTBC strains sub-cultured in Middlebrook 7H11 medium supplemented with 10% oleic-acid, dextrose, catalase growth supplement and incubated for up to 6 weeks at 37°C and using the following seven reference strains (M. tuberculosis H37Rv, M canettii, M. africanum, M. pinnipedii, M. caprae, M. bovis, and M. bovis BCG) grown under the same conditions, to set the reference lipid database and test it against the 90 MTBC clinical isolates. Cultured mycobacteria were heat-inactivated and loaded onto the matrix-assisted laser desorption/ionization target followed by the addition of the matrix. Acquisition of the data was performed using the positive ion mode. RESULTS: Based on the identification of clear and defined lipid signatures from the seven reference strains, the method that we developed was fast (<10 minutes) and produced interpretable profiles for all but four isolates, caused by poor ionization giving an n = 86 with interpretable spectra. The sensitivity and specificity of the matrix-assisted laser desorption/ionization time of flight were 94.4 (95% CI, 86.4-98.5) and 94.4 (95% CI, 72.7-99.9), respectively. CONCLUSIONS: Mycobacterial lipid profiling provides a means of rapid, safe, and accurate discrimination of species within the MTBC.