环介导等温扩增与超敏快速诊断试验在肯尼亚孕妇疟疾筛查中的诊断性能
在肯尼亚西部孕妇首次产前检查时,以PET-PCR为参考标准,比较专家镜检、常规快速诊断试验、超敏快速诊断试验和环介导等温扩增的诊断性能。482名筛查者中172人(35.7%)PET-PCR阳性,LAMP灵敏度最高(68.6%),其次为超敏快速诊断试验(54.7%)、常规快速诊断试验(49.4%)和专家镜检(40.1%)。在无发热孕妇中,超敏快速诊断试验对低密度感染的检测较常规快速诊断试验有中等程度改善。
要点
- 以PET-PCR为参考,LAMP灵敏度68.6%,超敏快速诊断试验54.7%,常规快速诊断试验49.4%,专家镜检40.1%。
- 无发热孕妇中,LAMP和超敏快速诊断试验分别检出比常规快速诊断试验更多的感染。
- 在无发热孕妇中,第一代超敏快速诊断试验对低密度感染的检测较常规快速诊断试验有中等程度改善。
核心结论
- 第一代超敏快速诊断试验在检测无发热孕妇低密度感染方面较常规快速诊断试验有中等程度改善。
研究设计与样本
- 在肯尼亚西部孕妇首次产前检查时连续纳入482名参与者,以Photoinduced electron-transfer polymerase chain reaction(PET-PCR)为参考标准,计算并建模低寄生虫密度下的诊断性能。
主要发现
- 2018年5月至9月,482名筛查参与者中172人(35.7%)PET-PCR阳性。
- 相对PET-PCR,专家镜检灵敏度最低(40.1%;95% CI,32.7%-47.9%),其次为常规快速诊断试验(49.4%;95% CI,41.7%-57.1)、超敏快速诊断试验(54.7%;95% CI,46.9%-62.2%)和LAMP(68.6%;95% CI,61.1%-75.5%)。
- 在90名发热孕妇中,各试验灵敏度相当。
- 按模型,各试验在密度>200个/µL时表现相似;在50个/µL时,专家镜检、常规快速诊断试验、超敏快速诊断试验和LAMP的灵敏度分别为45%、56%、62%和74%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Screen-and-treat strategies with sensitive diagnostic tests may reduce malaria-associated adverse pregnancy outcomes. We conducted a diagnostic accuracy study to evaluate new point-of-care tests to screen pregnant women for malaria at their first antenatal visit in western Kenya. METHODS: Consecutively women were tested for Plasmodium infection by expert microscopy, conventional rapid diagnostic test (cRDT), ultra sensitive RDT (usRDT), and loop-mediated isothermal amplification (LAMP). Photoinduced electron-transfer polymerase chain reaction (PET-PCR) served as the reference standard. Diagnostic performance was calculated and modelled at low parasite densities. RESULTS: Between May and September 2018, 172 of 482 screened participants (35.7%) were PET-PCR positive. Relative to PET-PCR, expert microscopy was least sensitive (40.1%; 95% confidence interval [CI], 32.7%-47.9%), followed by cRDT (49.4%; 95% CI, 41.7%-57.1), usRDT (54.7%; 95% CI, 46.9%-62.2%), and LAMP (68.6%; 95% CI, 61.1%-75.5%). Test sensitivities were comparable in febrile women (n = 90). Among afebrile women (n = 392), the geometric-mean parasite density was 29 parasites/µL and LAMP (sensitivity = 61.9%) and usRDT (43.2%) detected 1.74 (95% CI, 1.31-2.30) and 1.21 (95% CI, 88-2.21) more infections than cRDT (35.6%). Per our model, tests performed similarly at densities >200 parasites/µL. At 50 parasites/µL, the sensitivities were 45%, 56%, 62%, and 74% with expert microscopy, cRDT, usRDT, and LAMP, respectively. CONCLUSIONS: This first-generation usRDT provided moderate improvement in detecting low-density infections in afebrile pregnant women compared to cRDTs.
引用
- Samuels AM, Towett O, Seda B, et al. Diagnostic Performance of Loop-Mediated Isothermal Amplification and Ultrasensitive Rapid Diagnostic Tests for Malaria Screening Among Pregnant Women in Kenya. J Infect Dis. 2022. PMID: 35811308. doi:10.1093/infdis/jiac289
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。