文献速递结核与非结核分枝杆菌医院感染防控

预测空气传播感染风险:南非医务人员个人环境二氧化碳水平监测与结核感染发病率之间的关联

Predicting Airborne Infection Risk: Association Between Personal Ambient Carbon Dioxide Level Monitoring and Incidence of Tuberculosis Infection in South African Health Workers.
PubMed 文献 · Clin Infect Dis · 2022-01-01

在南非开普敦对138名医务人员分析基线和12个月重复的γ干扰素释放试验结果,并对基线QFT-Plus阴性者随机子集进行个人环境二氧化碳监测。结核感染年发病率达34%,IGRA阳转者中位二氧化碳水平高于未阳转者,中位二氧化碳水平可预测IGRA阳转(OR 2.04),中位二氧化碳每升高100 ppm,重复定量IGRA结果更高的比值比增加近2倍(OR 1.81)。

要点

  • 医务人员结核感染年发病率高(34%)。
  • IGRA阳转者中位二氧化碳水平高于未阳转者。
  • 中位二氧化碳每升高100 ppm,重复定量IGRA结果更高的OR为1.81。

核心结论

  • 医务人员面临高职业性结核风险,中位二氧化碳水平升高(提示通风不良和/或高占用率)与医务人员结核感染可能性更高相关。

研究设计与样本

  • 分析南非开普敦138名医务人员的基线和重复(12个月)γ干扰素释放试验结果,基线QFT-Plus阴性的随机子集接受个人环境二氧化碳监测。

主要发现

  • 结核感染(IGRA阳转)年发病率为34%。
  • 初级医生基线IGRA阳性的可能性低于其他医务人员(OR 0.26;P = .005),但IGRA阳转风险相似。
  • 采用QFT-Plus定量阈值≥0.35 IU/mL(P < .02)或≥1 IU/mL(P < .01)时,IGRA阳转者中位二氧化碳水平高于未阳转者。
  • 中位二氧化碳水平可预测IGRA阳转(OR 2.04;P = .04,≥1 IU/mL阈值)。
  • 有序逻辑回归显示,中位二氧化碳每升高100 ppm,重复定量IGRA结果更高的比值比增加近2倍(OR 1.81;P = .01),提示剂量依赖性反应。

临床怎么用

  • 个人环境二氧化碳监测可能有助于针对性地实施干预以降低医疗机构内结核传播,并帮助医务人员自我监测职业风险,对其他空气传播感染(包括2019冠状病毒病)具有意义。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: High rates of tuberculosis (TB) transmission occur in hospitals in high-incidence countries, yet there is no validated way to evaluate the impact of hospital design and function on airborne infection risk. We hypothesized that personal ambient carbon dioxide (CO2) monitoring could serve as a surrogate measure of rebreathed air exposure associated with TB infection risk in health workers (HWs). METHODS: We analyzed baseline and repeat (12-month) interferon-γ release assay (IGRA) results in 138 HWs in Cape Town, South Africa. A random subset of HWs with a baseline negative QuantiFERON Plus (QFT-Plus) underwent personal ambient CO2 monitoring. RESULTS: Annual incidence of TB infection (IGRA conversion) was high (34%). Junior doctors were less likely to have a positive baseline IGRA than other HWs (OR, 0.26; P = .005) but had similar IGRA conversion risk. IGRA converters experienced higher median CO2 levels compared to IGRA nonconverters using quantitative QFT-Plus thresholds of ≥0.35 IU/mL (P < .02) or ≥1 IU/mL (P < .01). Median CO2 levels were predictive of IGRA conversion (odds ratio [OR], 2.04; P = .04, ≥1 IU/mL threshold). Ordinal logistic regression demonstrated that the odds of a higher repeat quantitative IGRA result increased by almost 2-fold (OR, 1.81; P = .01) per 100 ppm unit increase in median CO2 levels, suggesting a dose-dependent response. CONCLUSIONS: HWs face high occupational TB risk. Increasing median CO2 levels (indicative of poor ventilation and/or high occupancy) were associated with higher likelihood of HW TB infection. Personal ambient CO2 monitoring may help target interventions to decrease TB transmission in healthcare facilities and help HWs self-monitor occupational risk, with implications for other airborne infections including coronavirus disease 2019.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Nathavitharana RR, Mishra H, Sullivan A, et al. Predicting Airborne Infection Risk: Association Between Personal Ambient Carbon Dioxide Level Monitoring and Incidence of Tuberculosis Infection in South African Health Workers. Clin Infect Dis. 2022. PMID: 35348657. doi:10.1093/cid/ciac183

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。