文献速递病毒性肝炎

即时检测或干血斑样本检测丙型肝炎病毒RNA的诊断准确性:一项系统综述

Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review.
PubMed 文献 · J Infect Dis · 2022-01-01

该系统综述评估即时检测和干血斑样本检测HCV RNA的诊断准确性,共纳入43项研究。Xpert HCV Viral Load Fingerstick即时检测与静脉血样本相比,HCV RNA检测的敏感度和特异度分别为99%和99%;干血斑与静脉血样本相比,敏感度和特异度分别为97%和100%。结论认为指尖采血和干血斑样本检测HCV RNA均具有极好的诊断准确性。

要点

  • Xpert HCV Viral Load Fingerstick即时检测与静脉血相比,HCV RNA检测敏感度99%、特异度99%。
  • 干血斑与静脉血相比,HCV RNA检测敏感度97%、特异度100%。
  • Xpert Fingerstick检测无效结果比例为6%,提示操作者培训和质控的重要性。

核心结论

  • 指尖采血和干血斑样本检测HCV RNA的各检测方法均观察到极好的诊断准确性。
  • Xpert HCV Viral Load Fingerstick检测后无效结果的比例凸显了操作者培训和质控项目的重要性。

研究设计与样本

  • 系统综述,检索文献数据库和会议报告以寻找符合条件的研究,采用Meta分析合并估计值。
  • 共识别359篇文章,纳入43项符合条件的研究。

主要发现

  • Xpert HCV Viral Load Fingerstick与静脉血样本比较(7项研究,987份样本),HCV RNA检测敏感度99%(95%CI 97%-99%),特异度99%(95%CI 94%-100%)。
  • Xpert HCV Viral Load Fingerstick与静脉血样本比较(7项研究,987份样本),HCV RNA定量敏感度100%(95%CI 93%-100%),特异度100%(95%CI 94%-100%)。
  • Xpert HCV Viral Load Fingerstick检测后无效结果的比例为6%(95%CI 3%-11%)。
  • 干血斑与静脉血样本比较(28项研究,3988份样本),HCV RNA检测敏感度97%(95%CI 95%-98%),特异度100%(95%CI 98%-100%)。
  • 干血斑与静脉血样本比较(28项研究,3988份样本),HCV RNA定量敏感度98%(95%CI 96%-99%),特异度100%(95%CI 95%-100%)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Finger-stick point-of-care and dried blood spot (DBS) hepatitis C virus (HCV) RNA testing increases testing uptake and linkage to care. This systematic review evaluated the diagnostic accuracy of point-of-care testing and DBS to detect HCV RNA. METHODS: Bibliographic databases and conference presentations were searched for eligible studies. Meta-analysis was used to pool estimates. RESULTS: Of 359 articles identified, 43 studies were eligible and included. When comparing the Xpert HCV Viral Load Fingerstick assay to venous blood samples (7 studies with 987 samples), the sensitivity and specificity for HCV RNA detection was 99% (95% confidence interval [CI], 97%-99%) and 99% (95% CI, 94%-100%) and for HCV RNA quantification was 100% (95% CI, 93%-100%) and 100% (95% CI, 94%-100%). The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing was 6% (95% CI, 3%-11%). When comparing DBS to venous blood samples (28 studies with 3988 samples) the sensitivity and specificity for HCV RNA detection was 97% (95% CI, 95%-98%) and 100% (95% CI, 98%-100%) and for HCV RNA quantification was 98% (95% CI, 96%-99%) and 100% (95% CI, 95%-100%). CONCLUSIONS: Excellent diagnostic accuracy was observed across assays for detection of HCV RNA from finger-stick and DBS samples. The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing highlights the importance of operator training and quality assurance programs.

来源:J Infect Dis,查看原文。版权归原作者所有。

引用

  1. Catlett B, Hajarizadeh B, Cunningham E, et al. Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review. J Infect Dis. 2022. PMID: 35150578. doi:10.1093/infdis/jiac049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。