文献速递医院感染防控新发突发、热带与寄生虫病

重症监护室新型冠状病毒肺炎患者使用高流量鼻导管氧疗或辅助机械通气时环境表面与空气的严重急性呼吸综合征冠状病毒2污染情况

Surfaces and Air Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 Using High-Flow Nasal Oxygenation or Assisted Mechanical Ventilation in Intensive Care Unit Rooms of Patients With Coronavirus Disease 2019.
PubMed 文献 · J Infect Dis · 2022-01-01

在单人间重症监护室中,对成人新型冠状病毒肺炎患者的表面和空气样本进行严重急性呼吸综合征冠状病毒2 RNA及活病毒检测,76%表面样本和30%空气样本检出病毒RNA,细胞培养未检出活病毒;辅助机械通气与高流量鼻导管氧疗房间的表面和空气病毒RNA水平无显著差异;实验模型提示采样前15小时内长椅表面可能曾存在感染性病毒。

要点

  • 76%表面样本和30%空气样本检出SARS-CoV-2 RNA,细胞培养未检出活病毒
  • 辅助机械通气与高流量鼻导管氧疗房间的表面和空气病毒RNA水平无显著差异
  • 实验模型提示采样前15小时内长椅表面可能曾存在感染性病毒

核心结论

  • 单人间重症监护室中新型冠状病毒肺炎患者周围环境表面污染广泛,高流量鼻导管系统未产生比机械通气系统更多的病毒气溶胶化。

研究设计与样本

  • 筛选单人间重症监护室成人新型冠状病毒肺炎患者的表面和空气样本,检测严重急性呼吸综合征冠状病毒2 RNA和活病毒。

主要发现

  • 100份表面样本中76%检出病毒RNA,40份空气样本中30%检出病毒RNA,细胞培养未检出活病毒。
  • 辅助机械通气房间与高流量鼻导管系统房间的表面和空气病毒RNA水平无显著差异。
  • 使用原创实验性SARS-CoV-2表面感染模型确定,患者房间内长椅表面在采样前15小时内可能曾存在感染性病毒。

临床怎么用

  • 作者认为,尽管研究样本中未检出SARS-CoV-2活病毒颗粒,实验模型证实重症监护病房需要执行严格的环境消毒程序以及经典的标准和飞沫防护措施。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Understanding patterns of environmental contamination by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is essential for infection prevention policies. METHODS: We screened surfaces and air samples from single-bed intensive-care unit rooms of adult patients with coronavirus disease 2019 (COVID-19) for SARS-CoV-2 RNA and viable viruses. RESULTS: We evidenced viral RNA environmental contamination in 76% of 100 surfaces samples and in 30% of 40 air samples without any viable virus detection by cell culture assays. No significant differences of viral RNA levels on surfaces and in ambient air were observed between rooms of patients with assisted mechanical ventilation and those of patients with a high-flow nasal cannula system. Using an original experimental SARS-CoV-2 infection model of surfaces, we determined that infectious viruses may have been present on benches within 15 hours before the time of sampling in patient rooms. CONCLUSIONS: We observed that SARS-CoV-2 environmental contamination around patients with COVID-19 hospitalized in single-bed ICU rooms was extensive and that a high-flow nasal cannula system did not generate more viral aerosolization than a mechanical ventilation system in patients with COVID-19. Despite an absence of SARS-CoV-2 viable particles in study samples, our experimental model confirmed the need to apply strict environmental disinfection procedures and classic standard and droplet precautions in ICU wards.

来源:J Infect Dis,查看原文。版权归原作者所有。

引用

  1. Lebreil AL, Greux V, Glenet M, et al. Surfaces and Air Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 Using High-Flow Nasal Oxygenation or Assisted Mechanical Ventilation in Intensive Care Unit Rooms of Patients With Coronavirus Disease 2019. J Infect Dis. 2022. PMID: 34788831. doi:10.1093/infdis/jiab564

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。