文献速递血栓与止血

最大24小时血小板计数下降幅度:用于改善中等概率4Ts评分患者肝素诱导性血小板减少症诊断的指标

Maximum 24-hour platelet count fall: Metric for improving the diagnosis of heparin-induced thrombocytopenia among patients with intermediate probability 4Ts scores.
PubMed 文献 · J Thromb Haemost · 2020-06-25

在推导队列(宾夕法尼亚大学158例)和验证队列(安大略省汉密尔顿四家医院139例)中,评估最大24小时血小板计数下降百分比(Fallmax)对中等概率4Ts评分疑似肝素诱导性血小板减少症(HIT)的鉴别价值。Fallmax在HIT阳性患者中显著更高,推导队列49.6% vs 38.6%(P=0.009),验证队列43.5% vs 29.3%(P=0.027);ROC曲线下面积分别为0.68(95%CI 0.57-0.78)和0.71(0.59-0.83)。Fallmax≥30%时,推导队列敏感度95.5%、特异度29.4%,验证队列敏感度80.0%、特异度52.7%。

要点

  • Fallmax在HIT阳性患者中显著高于HIT阴性患者:推导队列49.6% vs 38.6%(P=0.009),验证队列43.5% vs 29.3%(P=0.027)。
  • Fallmax≥30%时,推导队列敏感度95.5%、特异度29.4%,验证队列敏感度80.0%、特异度52.7%。
  • 使用考虑血小板下降速率的指标可能有助于避免对中等概率4Ts评分的HIT阴性患者不必要的停用肝素和替代抗凝治疗,但需进一步评估。

核心结论

  • 在疑似HIT且4Ts评分为中等概率的患者中,Fallmax有助于区分HIT阴性与HIT阳性患者。
  • 使用考虑血小板计数下降速率的指标可能有助于避免对中等概率4Ts评分的HIT阴性患者不必要的停用肝素和替代抗凝治疗,但需进一步评估。

研究设计与样本

  • 推导队列:宾夕法尼亚大学疑似HIT且4Ts评分为中等概率的患者158例。
  • 验证队列:安大略省汉密尔顿四家医院前瞻性收集的疑似HIT且4Ts评分为中等概率的患者139例。

主要发现

  • 推导队列中HIT阳性患者Fallmax为49.6%,HIT阴性患者为38.6%(P=0.009)。
  • 验证队列中HIT阳性患者Fallmax为43.5%,HIT阴性患者为29.3%(P=0.027)。
  • 推导队列ROC曲线下面积为0.68(95%CI 0.57-0.78),验证队列为0.71(95%CI 0.59-0.83)。
  • Fallmax≥30%时,推导队列敏感度95.5%、特异度29.4%,验证队列敏感度80.0%、特异度52.7%。

关键数值与推荐

  • Fallmax定义为最大24小时血小板计数下降百分比。
  • Fallmax≥30%作为阈值时,推导队列敏感度95.5%、特异度29.4%,验证队列敏感度80.0%、特异度52.7%。

临床怎么用

  • 作者认为,使用考虑血小板计数下降速率的指标可能有助于避免对中等概率4Ts评分的HIT阴性患者不必要的停用肝素和替代抗凝治疗,但需进一步评估。

局限性

  • 原文结论指出需进一步评估(further evaluation is warranted)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Most patients with suspected heparin-induced thrombocytopenia (HIT) and an intermediate probability 4Ts score do not have HIT. We aimed to develop a metric based on the rate of platelet count fall to aid in discriminating HIT status among patients with an intermediate 4Ts score. METHODS: We derived a measure of the maximum 24-hour percentage decrease in platelet count (Fallmax ) in a cohort of patients with suspected HIT and an intermediate 4Ts score at the University of Pennsylvania. We validated this metric in a prospectively collected cohort of patients with suspected HIT and an intermediate 4Ts score from four hospitals in Hamilton, Ontario. RESULTS: One hundred fifty-eight and 139 patients were included in the analysis from the derivation and validation cohorts, respectively. Fallmax was significantly higher in HIT-positive patients in the derivation cohort (49.6% versus 38.6%, P = .009) and validation cohort (43.5% versus 29.3%, P = .027). The area under the receiver operating characteristic curve was 0.68 (95% confidence interval [CI] 0.57-0.78) and 0.71 (0.59-0.83) in the two cohorts, respectively. At Fallmax ≥ 30%, sensitivity and specificity were 95.5% and 29.4% in the derivation cohort and 80.0% and 52.7% in the validation cohort. CONCLUSIONS: Among patients with suspected HIT and an intermediate 4Ts score, Fallmax aided in discriminating HIT-negative from HIT-positive patients. Using a measure that accounts for the rate of platelet count fall may help to avoid unnecessary suspension of heparin and treatment with an alternative anticoagulant in HIT-negative patients with an intermediate probability 4Ts score, though further evaluation is warranted.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Lefler DS, Cuker A, Linkins LA, et al. Maximum 24-hour platelet count fall: Metric for improving the diagnosis of heparin-induced thrombocytopenia among patients with intermediate probability 4Ts scores. J Thromb Haemost. 2020. PMID: 32430965. doi:10.1111/jth.14897