数字微滴PCR与里程碑分析检测F8 int22h倒位
该研究设计并验证了基于数字微滴PCR的里程碑分析,用于检测F8基因int22h倒位。通过检测锚定基因座与不同距离里程碑基因座的连接比例,并设计针对野生型及Inv22 1型和2型的特异性分析,在106例患者和20例携带者母亲中验证,结果与已知突变状态完全一致,且 assay 稳健性高。
要点
- 数字微滴PCR里程碑分析可检测F8 int22h倒位,与已知状态完全一致。
- 三种分析变异系数均<5%,输入DNA≥6 ng时稳健。
- 连接分子比例随基因座距离增加而下降,12-15 kb处为30%-40%。
核心结论
- 数字微滴PCR和里程碑分析可用于检测F8 int22h倒位。
- 该分析系统操作技术简单、高效且稳健。
研究设计与样本
- 使用数字微滴PCR里程碑分析研究存档DNA样本。
- 检测了106例患者和20例携带者母亲。
主要发现
- 连接分子比例随基因座间距离增加而降低,12至15 kb距离处显示30%至40%的连接分子。
- 针对野生型和Inv22 1型及2型染色体的里程碑分析均显示高特异性和敏感性,所有分析变异系数<5%。
- 106例患者和20例携带者母亲的分析与先前已知突变状态完全一致。
- 分析证实了 assay 对输入DNA浓度(6 ng及以上)和片段化水平的稳健性。
关键数值与推荐
- Inv22占所有严重血友病A患者的约45%。
- int22h重复序列大小约9.5 kb。
- 所有 assay 的变异系数<5%。
- 输入DNA浓度6 ng及以上时 assay 稳健。
临床怎么用
- 可替代传统长距离PCR和反向移位PCR用于F8 int22h倒位检测。
- 适用于存档DNA样本,所需DNA量低至6 ng。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Inversions involving intron 22 (Inv22) of F8 are detected in approximately 45% of all severe hemophilia A patients. Diagnosis is complicated by the large size of the ~9.5 kb int22h repeated sequence, which generates the inversions. Methods such as long-range polymerase chain reaction (PCR) and inverse-shifting PCR are currently used diagnostically, but suffer from low PCR efficiencies and are difficult to standardize. OBJECTIVES: To design and validate a sensitive and robust assay for the detection of F8 int22h inversions. METHODS: Digital droplet PCR using mile-post assays was used to investigate archival DNA samples. RESULTS: The detection of linkage as a function of physical distance between loci was investigated using an anchor locus and mile-post loci at 1, 6, 12 and 15 kb distances from the anchor locus. The proportion of linked molecules decreased with increasing distance between loci and showed 30% to 40% linked molecules for loci 12 to15 kb apart. Mile-post assays specific for wild type and Inv22 type 1 and 2 chromosomes were then designed and optimized. All three assays showed high specificities and sensitivities, with coefficients of variation <5% for all assays. Analysis of 106 patients and 20 carrier mothers showed complete concordance with previously known mutation status. The analysis demonstrated the robustness of the assays versus input DNA concentration (6 ng and higher) and level of fragmentation. CONCLUSIONS: Digital droplet PCR and mile-post assays can be used to detect F8 int22h inversions. The assay systems are technically simple to perform, highly efficient, and robust.
引用
- Manderstedt E, Lind-Halldén C, Ljung R, et al. Detection of F8 int22h inversions using digital droplet PCR and mile-post assays. J Thromb Haemost. 2020. PMID: 32031725. doi:10.1111/jth.14760
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。