5B9单克隆IgG模拟人抗体评估肝素诱导血小板减少症功能检测

Evaluation of functional assays for the diagnosis of heparin induced thrombocytopenia using 5B9, a monoclonal IgG that mimics human antibodies.
PubMed 文献 · J Thromb Haemost · 2020-02-20

本研究以模拟人HIT抗体的单克隆IgG 5B9评估多种功能检测法的性能,并与SRA对比。结果显示SRA与HIMEA在5B9 20 µg/mL时对全部供者阳性,FC为83%;SRA检测灵敏度最高,但HIMEA或FC可作为替代方法。

要点

  • SRA仍是检测致病性HIT抗体最敏感和特异的试验。
  • HIMEA在5B9 20 µg/mL时与SRA同样100%阳性。
  • FC在不确定/不太可能HIT样本中出现3例阳性或可疑。

核心结论

  • SRA可能仍是检测血小板活化性HIT抗体最敏感和特异的试验。
  • HIMEA或FC是潜在替代方法,但性能较低。

研究设计与样本

  • 使用5B9(50/20/10 µg/mL)在同一天用所有方法检测20名健康供者血小板的肝素依赖性活化。
  • 随后对3种对5B9最敏感的方法检测可能HIT(n=10)与不确定/不太可能HIT(n=10)患者样本。

主要发现

  • 所有方法对5B9 50 µg/mL均显示良好灵敏度。
  • 5B9 20 µg/mL时仅SRA和HIMEA对100%供者阳性,FC为83%。
  • 5B9 10 µg/mL时SRA对90%供者阳性,HIMEA和FC分别为45%和44%。
  • 可能HIT样本中SRA阳性9/10,HIMEA和FC分别阳性6和7例。
  • 不确定/不太可能HIT样本中SRA和HIMEA均未阳性,FC阳性或可疑3例。

临床怎么用

  • 在需要检测致病性HIT抗体时,SRA应作为首选参考方法。
  • 若SRA不可及,可考虑HIMEA或FC作为替代,但需理解其灵敏度较低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Serotonin release assay (SRA) is considered as the "gold standard" for detecting pathogenic heparin-induced thrombocytopenia (HIT) antibodies. However, this method is time consuming, expensive, and uses radioelements. Heparin-induced multiple electrode aggregometry (HIMEA), light transmission aggregometry (LTA) with platelet rich plasma (PRP) or washed platelets (WP), adenosine triphosphate (ATP) release, and flow cytometry (FC) are available alternatives. OBJECTIVES: To evaluate the performance of these assays, comparatively with SRA, for detecting HIT antibodies, using 5B9, a monoclonal IgG fully mimicking human HIT antibodies. PATIENTS/METHODS: Heparin-dependent platelet activation induced by 5B9 (50/20/10 µg/mL) was evaluated by all assays performed on the same day using platelets from 20 healthy donors. The three methods exhibiting the highest sensitivity to 5B9 were then assessed by testing samples from patients with either likely (n = 10), or indeterminate/unlikely HIT (n = 10). RESULTS: All methods exhibited good sensitivity for detecting 5B9 50 µg/mL, but only SRA and HIMEA were positive with 100% of donors using 5B9 20 µg/mL, followed by FC (83%). SRA detected 5B9 10 μg/mL with 90% of donors, while HIMEA and FC were positive in 45% and 44% of cases, respectively. Whereas SRA was positive with 9/10 samples from likely HIT, HIMEA and FC were positive with 6 and 7 of them, respectively. Neither SRA nor HIMEA was positive with indeterminate/unlikely HIT samples, while FC was positive or doubtful in three cases. CONCLUSIONS: Serotonin release assay likely remains the most sensitive and specific assay for detecting platelet activating HIT antibodies, but HIMEA or FC are potential alternatives, despite being less performant.

来源:J Thromb Haemost,查看原文。版权归原作者所有。