集成自动粒子追踪微流控实现红细胞疾病高通量细胞变形性检测
本研究将体外人工微血管网络与基于MATLAB的自动粒子追踪程序结合,实现高通量单细胞变形性指数(sDI)测量。应用于健康志愿者、镰状细胞病(SCD)患者、一名输血依赖型β地中海贫血重症患者及储存4周的浓缩红细胞,发现SCD患者存在高异质性生物物理亚群、β地中海贫血输血周期中sDI与红细胞大小曲线偏移、储存4天内出现低sDI亚群。
要点
- 该系统可高通量测量单个红细胞的变形性指数(sDI)和大小,类似流式细胞术进行二维分析。
- SCD患者红细胞sDI分布呈现高度异质性,表现为分布偏度和峰度值较大。
- β地中海贫血患者输血周期中sDI与红细胞大小曲线出现偏移,储存浓缩红细胞4天内出现低sDI亚群。
核心结论
- 该系统提供了一种廉价、便捷、高通量的方法测量任意红细胞群体的单细胞变形性和大小,有潜力辅助多种红细胞疾病的疾病监测和输血指南。
研究设计与样本
- 研究将体外人工微血管网络系统与基于MATLAB的自动粒子追踪程序配对,对健康志愿者、镰状细胞病(SCD)患者、一名输血依赖型β地中海贫血重症患者及储存4周的浓缩红细胞(pRBCs)进行单细胞变形性指数(sDI)测量。
主要发现
- SCD患者红细胞sDI分布呈现高度异质性,表现为分布偏度和峰度值较大。
- β地中海贫血患者输血周期中sDI与红细胞大小曲线出现偏移。
- 储存浓缩红细胞在4天内出现低sDI红细胞亚群。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Investigating individual red blood cells (RBCs) is critical to understanding hematologic diseases, as pathology often originates at the single-cell level. Many RBC disorders manifest in altered biophysical properties, such as deformability of RBCs. Due to limitations in current biophysical assays, there exists a need for high-throughput analysis of RBC deformability with single-cell resolution. To that end, we present a method that pairs a simple in vitro artificial microvasculature network system with an innovative MATLAB-based automated particle tracking program, allowing for high-throughput, single-cell deformability index (sDI) measurements of entire RBC populations. We apply our technology to quantify the sDI of RBCs from healthy volunteers, Sickle cell disease (SCD) patients, a transfusion-dependent beta thalassemia major patient, and in stored packed RBCs (pRBCs) that undergo storage lesion over 4 weeks. Moreover, our system can also measure cell size for each RBC, thereby enabling 2D analysis of cell deformability vs cell size with single cell resolution akin to flow cytometry. Our results demonstrate the clear existence of distinct biophysical RBC subpopulations with high interpatient variability in SCD as indicated by large magnitude skewness and kurtosis values of distribution, the "shifting" of sDI vs RBC size curves over transfusion cycles in beta thalassemia, and the appearance of low sDI RBC subpopulations within 4 days of pRBC storage. Overall, our system offers an inexpensive, convenient, and high-throughput method to gauge single RBC deformability and size for any RBC population and has the potential to aid in disease monitoring and transfusion guidelines for various RBC disorders.
引用
- Guruprasad P, Mannino RG, Caruso C, et al. Integrated automated particle tracking microfluidic enables high-throughput cell deformability cytometry for red cell disorders. Am J Hematol. 2018. PMID: 30417938. doi:10.1002/ajh.25345
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。