文献速递血栓与止血

年龄校正D-二聚体截断值可提高急诊科静脉血栓栓塞症诊断效率:四种检测方法的比较

Age-adjusted D-dimer cut-off leads to more efficient diagnosis of venous thromboembolism in the emergency department: a comparison of four assays.
PubMed 文献 · J Thromb Haemost · 2018-04-17

这项前瞻性单中心研究在940例急诊疑似肺栓塞或深静脉血栓的门诊患者中平行比较了四种D-二聚体检测方法,应用年龄校正截断值后所有检测方法的特异性提高6-7%,假阳性率总体降低6%,在≥70岁患者中降低10-20%,敏感性维持不变。

要点

  • 四种D-二聚体检测方法应用年龄校正截断值后AUC均>0.9,敏感性维持不变。
  • 年龄校正截断值使特异性提高6-7%,需检测人数减少<0.3。
  • 假阳性率总体降低6%,≥70岁患者降低10-20%。

核心结论

  • 年龄校正截断值使所有评估的D-二聚体检测方法维持高敏感性并适度改善特异性和需检测人数。
  • 假阳性结果显著减少,反映可避免的不必要影像检查且不损害临床安全性,提示可能使老年VTE患者的管理在临床和经济上获益。

研究设计与样本

  • 前瞻性单中心研究,纳入940例因临床疑似肺栓塞或深静脉血栓就诊于急诊科的门诊患者。
  • 平行比较四种自动化D-二聚体检测方法(Siemens INNOVANCE®、Roche Tina-quant、Medirox MRX和STA®-Liatest® D-Di PLUS),分别应用和不应用年龄校正截断值。

主要发现

  • 所有检测方法的ROC曲线下面积(AUC)均>0.9,实施年龄校正截断值后敏感性维持不变。
  • 特异性提高6-7%,需检测人数减少<0.3。
  • 假阳性率总体降低6%,≥70岁患者降低10-20%。

关键数值与推荐

  • 四种D-二聚体检测方法的AUC均>0.9。
  • 应用年龄校正截断值后特异性提高6-7%,需检测人数减少<0.3。
  • 假阳性率总体降低6%,≥70岁患者降低10-20%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Essentials Age-adjusted D-dimer cut-offs decrease the false positives in the elderly. Four D-dimer assays were compared in venous thromboembolism outpatients in an emergency ward. Age-adjusted cut-off resulted in improved specificity with maintained sensitivity for all assays. There was a substantial decrease in false positive results, especially in the older population. SUMMARY: Background The study compares different D-dimer assays and age-adjusted cut-offs in outpatients with suspected venous thromboembolism (VTE). The plasma concentration of this sensitive biomarker is increased by activated coagulation, but also by several conditions that are linked to an increased risk of VTE. One such condition is old age, which poses a common clinical problem where many prefer not to analyze D-dimer in elderly patients. Age-adjusted cut-offs have been validated for both deep venous thrombosis (DVT) and pulmonary embolism, aiming to increase specificity without notably decreasing sensitivity. Objectives We evaluated four common D-dimer assays in parallel, with and without applying age-adjusted cut offs for VTE. Patients/methods The prospective single-center study was conducted in 940 outpatients attending the emergency department with clinically suspected pulmonary embolism or DVT. Four automated D-dimer assays were compared (Siemens INNOVANCE® , Roche Tina-quant, Medirox MRX and STA® -Liatest® D-Di PLUS). Results All assays performed with areas under the ROC curve (AUC) > 0.9 and maintained their sensitivities after implementation of age-adjusted cut-offs. Specificities increased by 6-7% and number needed to test decreased by < 0.3. The rate of false positive results decreased by 6% overall and by 10-20% for patients ≥ 70. Conclusions Age-adjusted cut-offs resulted in maintained high sensitivity and a modest improvement in specificity and number needed to test for all evaluated D-dimer assays. There was a significant reduction in false positive results, which reflects avoidable unnecessary imaging without any compromise of clinical safety. This suggests a potential to benefit the management of VTE in elderly patients, both clinically and economically.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Farm M, Siddiqui AJ, Onelöv L, et al. Age-adjusted D-dimer cut-off leads to more efficient diagnosis of venous thromboembolism in the emergency department: a comparison of four assays. J Thromb Haemost. 2018. PMID: 29505695. doi:10.1111/jth.13994

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。