IgG特异性与多特异性酶联免疫分析在肝素诱导的血小板减少症中的诊断准确性:系统评价与荟萃分析

Diagnostic accuracy of IgG-specific versus polyspecific enzyme-linked immunoassays in heparin-induced thrombocytopenia: a systematic review and meta-analysis.
PubMed 文献 · J Thromb Haemost · 2017-05-11

该系统评价与荟萃分析纳入9项研究、1948例疑似肝素诱导的血小板减少症(HIT)患者,直接比较IgG特异性与多特异性酶联免疫分析(ELISA)的诊断准确性。结果显示两者敏感性相同(0.97),但IgG特异性ELISA特异性更高(0.87 vs 0.82),阳性预测值更优(0.56 vs 0.32),支持ISTH-SSC关于HIT实验室检测标准化的推荐。

要点

  • IgG特异性与多特异性ELISA敏感性相同(均为0.97)。
  • IgG特异性ELISA特异性高于多特异性(0.87 vs 0.82)。
  • IgG特异性ELISA阳性预测值优于多特异性(0.56 vs 0.32)。

核心结论

  • IgG特异性ELISA诊断准确性优于多特异性ELISA,支持ISTH-SSC关于HIT实验室检测标准化的推荐。

研究设计与样本

  • 系统检索纳入9项研究,共1948例疑似HIT患者,均同时接受IgG特异性和多特异性ELISA检测并有参考标准。
  • 采用QUADAS-2标准评估研究质量。

主要发现

  • IgG特异性与多特异性ELISA敏感性相同,均为0.97(95%CI 0.95-0.99)。
  • IgG特异性ELISA特异性为0.87(95%CI 0.85-0.88),高于多特异性ELISA的0.82(95%CI 0.80-0.84)。
  • IgG特异性与多特异性ELISA的阴性预测值均高(0.99,95%CI 0.99-1.00),但IgG特异性ELISA阳性预测值更优(0.56 [95%CI 0.52-0.61] vs 0.32 [95%CI 0.28-0.35])。
  • IgG特异性ELISA阳性似然比高于多特异性ELISA,阴性似然比相似。
  • 使用5-羟色胺释放试验和单一商业ELISA厂家的亚组中表现相似。

关键数值与推荐

  • IgG特异性ELISA敏感性0.97(95%CI 0.95-0.99),特异性0.87(95%CI 0.85-0.88)。
  • 多特异性ELISA敏感性0.97(95%CI 0.95-0.99),特异性0.82(95%CI 0.80-0.84)。
  • IgG特异性ELISA阳性预测值0.56(95%CI 0.52-0.61),多特异性ELISA阳性预测值0.32(95%CI 0.28-0.35)。
  • IgG特异性ELISA阴性预测值0.99(95%CI 0.99-1.00),多特异性ELISA阴性预测值0.99(95%CI 0.99-1.00)。

临床怎么用

  • 作者认为IgG特异性ELISA诊断准确性更优,支持ISTH-SSC关于HIT实验室检测标准化的推荐。
  • 作者提出单个检测的似然比可与临床评分系统结合,作为HIT整合诊断流程的一部分。

局限性

  • 指数试验和参考标准领域存在高质量关注风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Essentials Immunoassay specificity varies in heparin-induced thrombocytopenia (HIT) testing. This meta-analysis examined 9 studies that tested samples by both IgG and polyspecific methods. IgG-specific assays confer superior diagnostic accuracy compared with polyspecific assays. These results further support recommendations in favor of IgG-specific testing. SUMMARY: Background There are conflicting data on whether the IgG-specific or polyspecific antiplatelet factor 4/heparin (PF4/H) enzyme-linked immunosorbent assay (ELISA) is preferred for the laboratory diagnosis of heparin-induced thrombocytopenia (HIT). Objectives To directly compare diagnostic accuracy of IgG-specific versus polyspecific ELISA in HIT. Patients/Methods A systematic search yielded nine studies comprising 1948 patients with suspected HIT tested by both IgG-specific and polyspecific ELISAs and a reference standard against which the diagnostic accuracy of the ELISAs could be measured. Study quality was assessed by QUADAS-2 criteria. Results There was identical sensitivity for IgG-specific and polyspecific ELISAs (0.97; 95% confidence interval (CI), 0.95-0.99) and superior specificity of IgG-specific compared with polyspecific ELISA (0.87 [0.85-0.88] vs. 0.82 [0.80-0.84], respectively). Performance was similar in subgroups using the serotonin release assay and a single commercial ELISA manufacturer. The negative predictive values of IgG-specific and polyspecific ELISA were similarly high (0.99, [0.99-1.00], but the positive predictive value was superior with IgG-specific compared with polyspecific ELISA (0.56 [0.52-0.61] vs. 0.32 [0.28-0.35], respectively). The positive likelihood ratio (LR) was higher in IgG-specific than polyspecific ELISA, although negative LRs were similar. There was high risk of quality concerns in domains of index test and reference standard. Conclusions The superior diagnostic accuracy of IgG-specific ELISA reinforces the ISTH-SSC recommendation for standardization of laboratory testing for HIT. Likelihood ratios of individual assays may be used in combination with clinical scoring systems as part of an integrated diagnostic algorithm for HIT.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Husseinzadeh HD, Gimotty PA, Pishko AM, et al. Diagnostic accuracy of IgG-specific versus polyspecific enzyme-linked immunoassays in heparin-induced thrombocytopenia: a systematic review and meta-analysis. J Thromb Haemost. 2017. PMID: 28374939. doi:10.1111/jth.13692

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。