用于血友病A简化胚胎植入前遗传学诊断的F8基因1 Mb内单管十四重高多态性微卫星标记组合
研究评估了F8基因≤1 Mb范围内多个微卫星标记在177名女性中的多态性,筛选出13个高多态性标记与AMELX/Y indel二态性在单管反应中共扩增。该十四重组合在0.6 Mb内标记观察杂合度0.43–0.84,约70–80%个体对≥5个标记杂合,并在一对因F8基因内点突变需行PGD的夫妇中成功识别完全信息性标记。
要点
- 13个位于F8基因0.6 Mb内的高多态性微卫星标记可与AMELX/Y在单管反应中共扩增。
- 组分标记观察杂合度为0.43–0.84,约70–80%个体对≥5个标记杂合。
- 该组合可单独用于连锁分析,也可与含突变的F8扩增子共扩增用于联合突变检测与连锁分析。
核心结论
- 该高多态性微卫星标记组合的单管多重PCR形式简化了血友病A基于连锁分析的PGD中信息性标记的识别与选择。
研究设计与样本
- 在177名女性受试者中评估F8基因≤1 Mb范围内多个微卫星标记的多态性。
- 筛选高多态性标记与AMELX/Y indel二态性在单管反应中共扩增。
主要发现
- 13个位于F8基因0.6 Mb内的微卫星标记与AMELX/Y在单管反应中成功共扩增。
- 组分标记观察杂合度范围为0.43至0.84,约70–80%个体对≥5个标记杂合。
- 十四重组合在一对因F8基因内点突变需行PGD的夫妇中成功识别完全信息性标记,单倍型定相通过携带者女儿建立。
- 体外受精PGD包括单管共扩增完全信息性标记与AMELX/Y及含突变F8扩增子,随后进行微卫星分析和扩增子突变位点微测序分析。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
UNLABELLED: Essentials Preimplantation genetic diagnosis (PGD) of severe hemophilia A relies on linkage analysis. Simultaneous multi-marker screening can simplify selection of informative markers in a couple. We developed a single-tube tetradecaplex panel of polymorphic markers for hemophilia A PGD use. Informative markers can be used for linkage analysis alone or combined with mutation detection. SUMMARY: Background It is currently not possible to perform single-cell preimplantation genetic diagnosis (PGD) to directly detect the common inversion mutations of the factor VIII (F8) gene responsible for severe hemophilia A (HEMA). As such, PGD for such inversion carriers relies on indirect analysis of linked polymorphic markers. Objectives To simplify linkage-based PGD of HEMA, we aimed to develop a panel of highly polymorphic microsatellite markers located near the F8 gene that could be simultaneously genotyped in a multiplex-PCR reaction. Methods We assessed the polymorphism of various microsatellite markers located ≤ 1 Mb from F8 in 177 female subjects. Highly polymorphic markers were selected for co-amplification with the AMELX/Y indel dimorphism in a single-tube reaction. Results Thirteen microsatellite markers located within 0.6 Mb of F8 were successfully co-amplified with AMELX/Y in a single-tube reaction. Observed heterozygosities of component markers ranged from 0.43 to 0.84, and ∼70-80% of individuals were heterozygous for ≥ 5 markers. The tetradecaplex panel successfully identified fully informative markers in a couple interested in PGD for HEMA because of an intragenic F8 point mutation, with haplotype phasing established through a carrier daughter. In-vitro fertilization (IVF)-PGD involved single-tube co-amplification of fully informative markers with AMELX/Y and the mutation-containing F8 amplicon, followed by microsatellite analysis and amplicon mutation-site minisequencing analysis. Conclusions The single-tube multiplex-PCR format of this highly polymorphic microsatellite marker panel simplifies identification and selection of informative markers for linkage-based PGD of HEMA. Informative markers can also be easily co-amplified with mutation-containing F8 amplicons for combined mutation detection and linkage analysis.
引用
- Zhao M, Chen M, Tan ASC, et al. Single-tube tetradecaplex panel of highly polymorphic microsatellite markers < 1 Mb from F8 for simplified preimplantation genetic diagnosis of hemophilia A. J Thromb Haemost. 2017. PMID: 28345288. doi:10.1111/jth.13685
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。