CTPA与VQ扫描诊断肺栓塞的辐射暴露与早发癌症风险比较
中位随访5.26-6.96年,两组癌症发生率无显著差异(10.93 vs 10.98/1000人年,P=0.93),多变量分析风险比0.95(95%CI 0.86-1.05)。
要点
- CTPA与VQ扫描诊断肺栓塞后早发癌症风险无显著差异。
- 总体癌症发生率为10.96/1000人年(95%CI 10.42-11.52)。
- 多变量分析显示CTPA与VQ扫描风险比0.95(95%CI 0.86-1.05)。
核心结论
- 基于人群的队列中,CTPA暴露相关癌症风险未显著高于VQ肺扫描。
研究设计与样本
- 回顾性、基于人群的匹配队列研究,使用加拿大安大略省关联临床与行政健康数据库。
- 纳入2004至2021年诊断为肺栓塞的18至75岁患者,VQ扫描者按年龄和性别匹配至CTPA患者。
主要发现
- CTPA组中位随访5.26年,VQ组6.96年。
- 总体癌症发生率为10.96/1000人年(95%CI 10.42-11.52)。
- CTPA组癌症发生率为10.93/1000人年(95%CI 10.14-11.78),VQ组为10.98/1000人年(95%CI 10.26-11.75),P=0.93。
- 多变量分析显示CTPA与VQ扫描风险比0.95(95%CI 0.86-1.05)。
临床怎么用
- 在评估肺栓塞诊断成像选择时,CTPA与VQ扫描的早发癌症风险无显著差异,可结合其他临床因素决策。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Computed tomography pulmonary angiography (CTPA) and ventilation-perfusion (VQ) scans are used to diagnose pulmonary embolism (PE), but there are concerns about ionizing radiation exposure from CTPA and its potential to increase cancer risk. OBJECTIVES: This study compared early-onset cancer risk between patients diagnosed with PE who underwent CTPA or VQ imaging. METHODS: We conducted a retrospective, population-based, matched cohort study using linked clinical and administrative health databases in Ontario, Canada. Patients aged 18 to 75 years diagnosed with PE between 2004 and 2021 were included. Each patient who underwent a VQ scan was matched by age and sex to a patient who underwent CTPA. Using a landmark statistical framework, starting at 18 months post-PE diagnosis, cancer diagnoses were identified from the Ontario Cancer Registry. Cox proportional hazards regression models were used to assess the association between imaging modality and cancer risk. RESULTS: A total of 20 476 patients were included, 10 238 in each cohort. The median follow-up was 5.26 years for patients in the CTPA group and 6.96 years for those in the VQ group. The overall cancer rate was 10.96 per 1000 person-years (95% CI, 10.42-11.52). There was no significant difference in cancer risk between the CTPA (10.93 per 1000 person-years; 95% CI, 10.14-11.78) and VQ scan groups (10.98 per 1000 person-years; 95% CI, 10.26-11.75; P = .93). Multivariable analysis demonstrated no significant association between CTPA and VQ scan (hazard ratio, 0.95; 95% CI, 0.86-1.05). CONCLUSIONS: In this population-based cohort, cancer risk associated with exposure to CTPA was not significantly higher than that associated with VQ lung scans.
引用
- Simard C, Siegal DM, Nguyen L, et al. Comparative analysis of radiation exposure from computed tomography and ventilation-perfusion scans in the diagnosis of pulmonary embolism: an early-onset cancer risk assessment. J Thromb Haemost. 2025. PMID: 41397561. doi:10.1016/j.jtha.2025.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。