新型检测法快速识别产后出血及急性产科凝血病中的纤溶激活
研究开发了纤溶活性筛查试验(FAST),可在5分钟内检测血浆内源性纤溶酶活性。对33例产后出血(PPH)患者和20例择期剖宫产前孕妇的存档血浆分析显示,FAST检测的纤溶酶活性可区分急性产科凝血病(AOC)与非AOC的PPH(P=.0007)及对照(P<.0001),并与纤溶酶-抗纤溶酶复合物和D-二聚体强相关。
要点
- FAST可在5分钟内检测血浆纤溶酶活性,与纤溶酶-抗纤溶酶复合物升高强相关。
- 33例PPH中12例纤溶酶-抗纤溶酶复合物>25 000 ng/mL,符合AOC诊断标准。
- FAST测得的纤溶酶活性可区分AOC与非AOC的PPH(P=.0007)及孕妇对照(P<.0001)。
核心结论
- FAST检测法是产后女性中快速检测与AOC相关的纤溶激活的工具。
研究设计与样本
- 研究分析33例PPH女性和20例择期剖宫产前孕妇的存档血浆样本。
主要发现
- 33例PPH患者中12例纤溶酶-抗纤溶酶复合物>25 000 ng/mL,符合AOC诊断标准。
- FAST测得的纤溶酶活性区分AOC与非AOC的PPH(P=.0007),并区分AOC与孕妇非PPH对照组(P<.0001)。
- FAST测得的纤溶酶活性与纤溶酶-抗纤溶酶复合物和D-二聚体水平均强相关。
- 在行ROTEM检测的PPH患者中,18例无AOC者均无ROTEM定义的纤溶亢进,9例AOC者中有9例有ROTEM定义的纤溶亢进。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Postpartum hemorrhage (PPH) remains the leading cause of pregnancy-related mortality worldwide. Regardless of the initiating cause, continued bleeding may progress to a systemic coagulopathy. This coagulopathy may be complicated further by profound fibrinolytic activation that progresses to systemic hyperfibrinolysis, a condition that we have termed acute obstetric coagulopathy (AOC). Patients with placental abruption or amniotic fluid embolism are among those at highest risk for AOC. In response to the unmet need for a rapid method to detect fibrinolytic activation in this scenario, we developed a novel assay that we have termed the fibrinolytic activity screening test (FAST). This assay measures endogenously generated plasmin activity in plasma within 5 minutes. Its high sensitivity for the detection of in vivo fibrinolytic activation was confirmed by strong correlation with elevated plasmin-antiplasmin (PAP) complex levels. We analyzed archived plasma samples from 33 women with PPH and 20 pregnant women just before elective cesarean delivery. Of the 33 patients with PPH, 12 had PAP complex levels >25 000 ng/mL, thereby meeting criteria for the diagnosis of AOC. Plasmin activity measured by the FAST assay differentiated AOC from non-AOC PPH (P = .0007) and from pregnant non-PPH control groups (P< .0001) and was strongly correlated with both PAP complex and D-dimer levels. Among patients with PPH for whom viscoelastic whole blood testing (ROTEM) was performed, none of the 18 without AOC or 9 of those with AOC had evidence of ROTEM-defined hyperfibrinolysis. The FAST assay is a rapid tool to detect activation of fibrinolysis associated with AOC in women after delivery.
引用
- Ilich A, Whyte CS, Moonla C, et al. Rapid detection of fibrinolytic activation in postpartum hemorrhage and acute obstetric coagulopathy using a novel assay. Blood Adv. 2026. PMID: 41441916. doi:10.1182/bloodadvances.2025018775
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。