急性运动激发与镰状细胞贫血青少年的气道动力学:一项多中心研究
这项多中心研究纳入10-21岁非哮喘镰状细胞贫血(SCA)患者与种族匹配对照,比较最大心肺运动试验(CPET)和可控强度间歇试验(CIIT)后运动诱发性支气管痉挛(EIB)的发生率。CPET后EIB比例SCA组21% vs 对照组26%(p=0.537),CIIT后32% vs 17%(p=0.126),校正模型中SCA状态与EIB均无关联。
要点
- SCA患者与对照在CPET后EIB比例无显著差异(21% vs 26%,p=0.537)。
- CIIT后EIB比例两组无显著差异(SCA组32% vs 对照组17%,p=0.126)。
- 校正模型中SCA状态与CPET或CIIT后EIB均无关联。
核心结论
- 在最大CPET或持续时间更长的次最大运动激发后,SCA患者EIB并不比对照组更常见。
- 需要进一步研究以指导运动指南制定并更好理解运动对SCA气道动力学的影响。
研究设计与样本
- 多中心研究,纳入10-21岁非哮喘SCA患者及种族匹配对照。
- 受试者接受最大心肺运动试验(CPET,功率自行车)和可控强度间歇试验(CIIT,八轮恒定负荷骑行,随机分配至峰值负荷的50%或70%)。
- 运动前后进行肺量计检查,采用多变量logistic回归模型检验SCA状态与CPET及CIIT后EIB的关联。
主要发现
- 与对照组相比,SCA组血红蛋白更低、基线肺量计值更低、CPET最大负荷更低。
- 两组基线下气道阻塞及CPET、CIIT完成率相似,无不良事件发生。
- CPET后符合EIB标准的比例SCA组21% vs 对照组26%(p=0.537),无显著差异。
- CIIT后符合EIB标准的比例SCA组32% vs 对照组17%(p=0.126),无显著差异。
- 校正模型中SCA状态与CPET后或CIIT后EIB均无关联。
局限性
- 需要进一步研究以指导运动指南制定并更好理解运动对SCA气道动力学的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Sickle cell anemia (SCA) leads to reduced physical functioning and cardiopulmonary fitness. Prior studies suggest that airway hyperresponsiveness to bronchoprovocation testing is common in SCA, but the prevalence of exercise-induced bronchospasm (EIB) is understudied. We hypothesized that EIB is more common in children with SCA than in controls. Non-asthmatic subjects 10-21 years old with SCA and race-matched controls underwent (1) maximal Cardiopulmonary Exercise Testing (CPET) by cycle ergometry and (2) a Controlled Intensity Interval Test (CIIT) consisting of eight bouts of constant workload cycling, randomized to 50% (moderate) or 70% (vigorous) of peak workload. Spirometry was performed pre/post CPET and CIIT. Multivariable logistic regression models tested associations between SCA status and EIB in response to CPET and CIIT. Compared to controls, subjects with SCA demonstrated lower hemoglobin, reduced baseline spirometry values, and decreased CPET maximal workload. Baseline lower airway obstruction and completion rates for CPET and CIIT were similar between groups. No adverse events occurred. The percentage of participants who met criteria for EIB did not differ between subjects and controls after CPET (21% vs. 26%, p = 0.537) or CIIT (32% vs. 17%, p = 0.126). In adjusted models, SCA status was not associated with EIB after CPET or CIIT. EIB was not more common in subjects with SCA versus controls after maximal CPET or submaximal exercise challenge of longer duration. Further research is needed to inform the development of exercise guidelines and to better understand the effects of exercise on airway dynamics in SCA. Trial Registration: ClinicalTrials.gov identifier: NCT03653676.
引用
- Cohen RT, Hankins JS, Ness KK, et al. Acute Exercise Challenge and Airway Dynamics in Youth With Sickle Cell Anemia: A Multicenter Study. Am J Hematol. 2025. PMID: 41422377. doi:10.1002/ajh.70170
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。