SY-2101是新型口服三氧化二砷(ATO)制剂。这项1期研究在15例急性早幼粒细胞白血病(APL)患者中评估SY-2101与静脉ATO单次及多次给药后的药代动力学、安全性和耐受性,以及食物对SY-2101药代动力学的影响。结果显示空腹状态下SY-2101基于活性代谢物亚砷酸的全身暴露与静脉ATO相当,SY-2101可随餐或空腹给药,耐受性良好,大多数不良事件为低级别。
要点
- 空腹SY-2101与静脉ATO的AUC0-last和AUC0-inf几何均值比均为1.00,Cmax几何均值比为0.76。
- SY-2101餐后与空腹相比AUC0-last、AUC0-inf和Cmax几何均值比分别为1.08、1.12和0.85,可随餐或空腹给药。
- SY-2101耐受性良好,大多数不良事件为低级别。
核心结论
- 本研究提供了首个直接比较SY-2101与静脉ATO的患者内药代动力学交叉结果,支持两种制剂临床等效的可能性。
研究设计与样本
- 这项1期研究在15例急性早幼粒细胞白血病患者中评估SY-2101与静脉ATO单次及多次给药后的药代动力学、安全性和耐受性,以及食物对SY-2101药代动力学的影响。
- 试验注册号为NCT04996030。
主要发现
- 空腹状态下SY-2101基于活性代谢物亚砷酸[As(III)]的全身暴露与静脉ATO相当,SY-2101与静脉ATO的AUC0-last和AUC0-inf几何均值比均为1.00。
- SY-2101与静脉ATO的Cmax几何均值比为0.76,原文指出这因给药途径不同而在预期之中。
- SY-2101餐后与空腹相比,AUC0-last、AUC0-inf和Cmax的几何均值比分别为1.08、1.12和0.85。
- SY-2101耐受性良好,大多数不良事件为低级别。
关键数值与推荐
- 空腹SY-2101与静脉ATO的AUC0-last几何均值比为1.00,AUC0-inf几何均值比为1.00,Cmax几何均值比为0.76。
- SY-2101餐后与空腹的AUC0-last几何均值比为1.08,AUC0-inf几何均值比为1.12,Cmax几何均值比为0.85。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
SY-2101 is a novel oral formulation of arsenic trioxide (ATO). Although IV ATO in combination with all trans retinoic acid is highly efficacious in treating acute promyelocytic leukemia (APL), there remains a significant unmet need due to the treatment burden associated with receiving daily ATO infusions for nearly a year and the risk of complications associated with indwelling central catheters. The pharmacokinetics (PK), safety, and tolerability of SY-2101 and ATO IV after single- and multiple-dose administration and the impact of food on PK for SY-2101 were evaluated in this phase 1 study in 15 participants with APL. SY-2101 in the fasted state demonstrated comparable systemic exposure to ATO IV based on the active metabolite arsenious acid [As(III)], with geometric mean ratios (GMRs) of SY-2101 to ATO IV of 1.00 for area under the plasma concentration (AUC) from 0 hour to last time point (AUC0-last) and from 0 hour to infinity (AUC0-inf). The GMR of SY-2101 to ATO IV maximum concentration (Cmax) was 0.76, as was expected due to the different routes of administration. Comparisons of SY-2101 in fed to fasted states demonstrated similar exposure with GMRs of AUC0-last, AUC0-inf, and Cmax at 1.08, 1.12, and 0.85, respectively, allowing for SY-2101 administration with or without food. SY-2101 was well tolerated. Most adverse events were of low grade. This study provides the first intrapatient PK crossover results directly comparing SY-2101 with ATO IV and supports the likelihood of clinical equivalence between the 2 formulations. This trial was registered at www.ClinicalTrials.gov as #NCT04996030.
引用
- Ravandi F, Rangaraju S, Kantarjian H, et al. A pharmacokinetic and safety study of oral arsenic trioxide in patients with acute promyelocytic leukemia. Blood Adv. 2025. PMID: 40020161. doi:10.1182/bloodadvances.2024015453
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。