文献速递血栓与止血

以少胜多:低滴度O型全血减少总输血量并与严重创伤性出血成人存活独立相关

Doing more with less: low-titer group O whole blood resulted in less total transfusions and an independent association with survival in adults with severe traumatic hemorrhage.
PubMed 文献 · J Thromb Haemost · 2023-10-04

这项观察性研究纳入348例启动大量输血方案的成人创伤患者(成分输血180例,低滴度O型全血168例),低滴度O型全血组24小时未调整死亡率低于成分输血组(8% vs 19%,P=0.003),多变量Cox回归显示低滴度O型全血与24小时死亡率降低独立相关(HR 0.21,95%CI 0.07-0.67,P=0.004),且72小时总血制品用量更少。

要点

  • 低滴度O型全血组24小时未调整死亡率为8%,成分输血组为19%(P=0.003)。
  • 多变量Cox回归显示低滴度O型全血与24小时死亡率降低独立相关(HR 0.21,95%CI 0.07-0.67,P=0.004)。
  • 低滴度O型全血组72小时总血制品用量为48.9 mL/kg,成分输血组为80.9 mL/kg(P<0.001)。

核心结论

  • 在这项假设生成性研究中,低滴度O型全血的使用与24小时存活改善独立相关,主要在休克或凝血病患者中。
  • 低滴度O型全血还使血制品使用减少40%,相当于输注产品中位数减少2.4 L。

研究设计与样本

  • 观察性研究,纳入启动大量输血方案的成人创伤患者348例,其中成分输血组180例,低滴度O型全血组168例。
  • 主要结局为24小时死亡率,次要结局包括72小时总血制品使用,采用Cox回归确定与24小时死亡率的独立关联。

主要发现

  • 未调整24小时死亡率低滴度O型全血组为8%,成分输血组为19%(P=0.003),但6小时和28天死亡率相似。
  • 多变量Cox回归调整后,低滴度O型全血与24小时死亡率降低独立相关(HR 0.21,95%CI 0.07-0.67,P=0.004)。
  • 低滴度O型全血组72小时总血制品用量为48.9(25.9-106.9)mL/kg,成分输血组为80.9(41.6-139.3)mL/kg(P<0.001)。
  • 分层24小时存活分析中,低滴度O型全血与休克或凝血病患者存活改善相关。
  • 非O型患者使用低滴度O型全血与死亡率、器官损伤或不良事件增加无关。

局限性

  • 原文称本研究为假设生成性研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Low-titer group O whole blood (LTOWB) or component therapy (CT) may be used to resuscitate hemorrhaging trauma patients. LTOWB may have clinical and logistical benefits and may improve survival. OBJECTIVES: We hypothesized LTOWB would improve 24-hour survival in hemorrhaging patients and would be safe and equally efficacious in non-group O compared with group O patients. METHODS: Adult trauma patients with massive transfusion protocol activations were enrolled in this observational study. The primary outcome was 24-hour mortality. Secondary outcomes included 72-hour total blood product use. A Cox regression determined the independent associations with 24-hour mortality. RESULTS: In total, 348 patients were included (CT, n = 180; LTOWB, n = 168). Demographics were similar between cohorts. Unadjusted 24-hour mortality was reduced in LTOWB vs CT: 8% vs 19% (P = .003), but 6-hour and 28-day mortality were similar. In an adjusted analysis with multivariable Cox regression, LTOWB was independently associated with reduced 24-hour mortality (hazard ratio, 0.21; 95% CI, 0.07-0.67; P = .004). LTOWB patients received significantly less 72-hour total blood products (80.9 [41.6-139.3] mL/kg vs 48.9 [25.9-106.9] mL/kg; P < .001). In stratified 24-hour survival analyses, LTOWB was associated with improved survival for patients in shock or with coagulopathy. LTOWB use in non-group O patients was not associated with increased mortality, organ injury, or adverse events. CONCLUSION: In this hypothesis-generating study, LTOWB use was independently associated with improved 24-hour survival, predominantly in patients with shock or coagulopathy. LTOWB also resulted in a 40% reduction in blood product use which equates to a median 2.4 L reduction in transfused products.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Shea SM, Mihalko EP, Lu L, et al. Doing more with less: low-titer group O whole blood resulted in less total transfusions and an independent association with survival in adults with severe traumatic hemorrhage. J Thromb Haemost. 2023. PMID: 37797692. doi:10.1016/j.jtha.2023.09.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。