计算流式细胞术可准确评估慢性淋巴细胞白血病可测量残留病
研究开发基于FlowSOM的计算流程评估慢性淋巴细胞白血病(CLL)可测量残留病(MRD),在含456份样本的多个验证队列中,典型CLL计算MRD与专家分析高度相关(Pearson r > 0.99),二分类一致性>98%,并在少数专家未检出MRD的非典型CLL中检出疾病。
要点
- 基于FlowSOM的计算流程可自动化分析CLL的MRD,减少人工判读偏倚。
- 典型CLL中计算MRD与专家分析高度相关(Pearson r > 0.99),二分类一致性>98%。
- 计算MRD在少数专家未检出MRD的非典型CLL病例中检出疾病。
核心结论
- 结果表明自动化流式细胞术分析在诊断实验室中具有可行性和价值。
研究设计与样本
- 研究开发了基于FlowSOM的计算流程评估CLL的MRD,训练步骤生成自组织映射图,节点代表正常未成熟和成熟B细胞及疾病免疫表型。
- 该图用于多个验证队列共456份样本的MRD检测,包括非典型CLL病例和来自两个不同实验室的样本。
主要发现
- 典型CLL中计算MRD与专家分析高度相关(Pearson r > 0.99)。
- 典型CLL样本二分类为MRD阳性或阴性的一致性>98%。
- 计算MRD在少数专家分析未检出MRD的非典型CLL病例中检出疾病。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Undetectable measurable residual disease (MRD) is associated with favourable clinical outcomes in chronic lymphocytic leukaemia (CLL). While assessment is commonly performed using multiparameter flow cytometry (MFC), this approach is associated with limitations including user bias and expertise that may not be widely available. Implementation of unsupervised clustering algorithms in the laboratory can address these limitations and have not been previously reported in a systematic quantitative manner. We developed a computational pipeline to assess CLL MRD using FlowSOM. In the training step, a self-organising map was generated with nodes representing the full breadth of normal immature and mature B cells along with disease immunophenotypes. This map was used to detect MRD in multiple validation cohorts containing a total of 456 samples. This included an evaluation of atypical CLL cases and samples collected from two different laboratories. Computational MRD showed high correlation with expert analysis (Pearson's r > 0.99 for typical CLL). Binary classification of typical CLL samples as either MRD positive or negative demonstrated high concordance (>98%). Interestingly, computational MRD detected disease in a small number of atypical CLL cases in which MRD was not detected by expert analysis. These results demonstrate the feasibility and value of automated MFC analysis in a diagnostic laboratory.
引用
- Nguyen PC, Nguyen V, Baldwin K, et al. Computational flow cytometry provides accurate assessment of measurable residual disease in chronic lymphocytic leukaemia. Br J Haematol. 2023. PMID: 37052611. doi:10.1111/bjh.18802
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。