文献速递血栓与止血

通过福斯特共振能量转移丢失监测血浆中凝血酶原活化

Monitoring prothrombin activation in plasma through loss of Förster resonance energy transfer.
PubMed 文献 · J Thromb Haemost · 2023-03-15

该研究开发了一种基于福斯特共振能量转移丢失的血浆检测法,直接监测凝血酶原因子R271位点切割,不依赖荧光底物。结果显示,凝血因子V可用性显著影响凝血酶原活化速率;凝血因子VIII和IX先天性缺乏在外源和内源途径凝血中均显著减慢R271切割,而凝血因子XI缺乏仅在内源途径触发时受影响。

要点

  • 新方法通过福斯特共振能量转移丢失直接监测凝血酶原R271位点切割,无需荧光底物。
  • 凝血因子V可用性显著影响凝血酶原活化速率,凝血酶生成速率在凝血因子V或凝血酶原耗竭血浆中受到同等干扰。
  • 先天性凝血因子VIII和IX缺乏显著减慢外源和内源途径凝血中R271切割;凝血因子XI缺乏仅在内源途径触发时受影响。

核心结论

  • 福斯特共振能量转移检测法无需荧光底物即可通过R271切割直接监测凝血酶原活化,且灵敏度足以评估凝血因子缺乏对凝血酶生成的影响。

研究设计与样本

  • 研究开发了一种血浆检测法,通过福斯特共振能量转移丢失监测凝血酶原R271位点切割,在外源或内源途径凝血的血浆中进行。

主要发现

  • 凝血因子V可用性强烈影响凝血酶原活化速率,凝血酶生成速率在凝血因子V或凝血酶原耗竭血浆中受到同等干扰。
  • 先天性凝血因子VIII和IX缺乏显著减慢外源和内源途径凝血中R271切割。
  • 凝血因子XI缺乏血浆中凝血酶原活化仅在内源途径触发凝血时受到干扰。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current assays that monitor thrombin generation in plasma rely on fluorogenic substrates to follow the kinetics of zymogen activation, which may be complicated by substrate cleavage from other proteases. In addition, these assays depend on activation following cleavage at the prothrombin R320 site and fail to report the cleavage at the alternative R271 site, leading to the shedding of the auxiliary Gla and kringle domains of prothrombin. OBJECTIVES: To develop a plasma assay that directly monitors prothrombin activation independent of fluorogenic substrate hydrolysis. METHODS: Cleavage at the R271 site of prothrombin is monitored through loss of Förster resonance energy transfer in plasma coagulated along the extrinsic or intrinsic pathway. RESULTS: The availability of factor (F)V in plasma strongly influences the rate of prothrombin activation. The rate of thrombin formation is equally perturbed in FV or prothrombin-depleted plasma, implicating that the thrombin-catalyzed feedback reactions that amplify the coagulation response play an important role in generating sufficient amounts of FVa required for the assembly of prothrombinase. Congenital deficiencies in FVIII and FIX significantly slow down cleavage at R271 in plasma coagulated along the extrinsic and intrinsic pathways. Prothrombin activation in FXI-deficient plasma is only perturbed when coagulation is triggered along the intrinsic pathway. CONCLUSION: The Förster resonance energy transfer assay enables direct monitoring of prothrombin activation through cleavage at R271 without the need for fluorogenic substrates. The assay is sensitive enough to assess how deficiencies in coagulation factors affect thrombin formation.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Stojanovski BM, Di Cera E. Monitoring prothrombin activation in plasma through loss of Förster resonance energy transfer. J Thromb Haemost. 2023. PMID: 36931601. doi:10.1016/j.jtha.2023.03.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。