文献速递血栓与止血

全F9基因测序在遗传学未解的血友病B患者中识别深部内含子变异

Whole F9 gene sequencing identified deep intronic variations in genetically unresolved hemophilia B patients.
PubMed 文献 · J Thromb Haemost · 2022-12-22

对17例常规遗传学检查未明确致病变异的血友病B患者行全F9基因测序,共检出9个候选变异,经计算机分析和微基因试验评估剪接影响,最终在13/17(76%)家系中明确致病变异。

要点

  • 对常规遗传学检查未解的血友病B患者行全F9测序可提高致病变异检出率。
  • 检出9个候选变异,其中c.278-1806A>C见于4个无关个体,c.278-1244A>G合并c.392-864T>G见于6个无关个体。
  • 微基因试验显示4个替换及c.278-1786_278-1785insLINE对剪接有有害影响。

核心结论

  • 全F9测序在13/17(76%)家系中明确了血友病B的致病变异,并报告了可导致血友病B的新F9深部内含子变异。

研究设计与样本

  • 对17例遗传学未解的血友病B患者行全F9基因测序,并用计算机分析(MaxEntScan和spliceAI)及微基因试验研究候选变异的致病影响。

主要发现

  • 共在15例患者中检出9个候选变异,其中7个为深部内含子替换,2个为移动元件插入。
  • 最常见的变异为c.278-1806A>C(4个无关个体)及c.278-1244A>G合并c.392-864T>G(6个无关个体)。
  • 计算机分析预测4个替换(c.278-1806A>C、c.392-864T>G、c.724-2385G>T、c.723+4297T>A)影响剪接,微基因试验显示这4个替换及c.278-1786_278-1785insLINE对剪接有有害影响。
  • 按美国医学遗传学与基因组学学会指南,5个变异归类为可能致病,4个归类为意义不明。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The disease-causative variant remains unidentified in approximately 0.5% to 2% of hemophilia B patients using conventional genetic investigations, and F9 deep intronic variations could be responsible for these phenotypes. OBJECTIVES: This study aimed to characterize deep intronic variants in hemophilia B patients for whom genetic investigations failed. METHODS: We performed whole F9 sequencing in 17 genetically unsolved hemophilia B patients. The pathogenic impact of the candidate variants identified was studied using both in silico analysis (MaxEntScan and spliceAI) and minigene assay. RESULTS: In total, 9 candidate variants were identified in 15 patients; 7 were deep intronic substitutions and 2 corresponded to insertions of mobile elements. The most frequent variants found were c.278-1806A>C and the association of c.278-1244A>G and c.392-864T>G, identified in 4 and 6 unrelated individuals, respectively. In silico analysis predicted splicing impact for 4 substitutions (c.278-1806A>C, c.392-864T>G, c.724-2385G>T, c.723+4297T>A). Minigene assay showed a deleterious splicing impact for these 4 substitutions and also for the c.278-1786_278-1785insLINE. In the end, 5 variants were classified as likely pathogenic using the American College of Medical Genetics and Genomics guidelines, and 4 as of unknown significance. Thus, the hemophilia B-causing variant was identified in 13/17 (76%) families. CONCLUSION: We elucidated the causing defect in three-quarters of the families included in this study, and we reported new F9 deep intronic variants that can cause hemophilia B.

来源:J Thromb Haemost,查看原文。版权归原作者所有。

引用

  1. Dericquebourg A, Fretigny M, Chatron N, et al. Whole F9 gene sequencing identified deep intronic variations in genetically unresolved hemophilia B patients. J Thromb Haemost. 2022. PMID: 36696202. doi:10.1016/j.jtha.2022.12.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。