文献速递消化内镜胰腺与胆道疾病

内镜下乳头切除术电外科设备最佳模式与功率输出的动物实验及初步临床研究

Optimal mode and power output of electrosurgical units for endoscopic papillectomy based on animal experiments and a preliminary clinical study (with videos).
PubMed 文献 · Gastrointest Endosc · 2021-10-19

本研究通过动物实验探讨内镜下乳头切除术(EP)的最佳电外科设备(ESU)设置,确定VIO设备endoCUT模式下切口力主要受持续时间影响,凝血效果与效应和持续时间均相关,并据此提出「VIO EP模式」。初步临床研究中未出现出血、胰腺炎或穿孔等显著不良事件。

要点

  • 切口力的主要影响因素为持续时间,凝血效果与效应及持续时间均相关。
  • knife-setting较snare-setting切口力更高、凝血效果更低。
  • 初步临床研究中「VIO EP模式」未出现显著不良事件。

核心结论

  • 基于动物实验确定的「VIO EP模式」似乎能实现最佳的乳头切除术效果。
  • 需要更大规模的临床研究积累数据并与ICC电外科设备进行临床比较。

研究设计与样本

  • 动物实验:采用鸡肉、猪肝和活猪建立专用动物实验模型,比较knife-setting与snare-setting endoCUT模式及不同效应、持续时间、间隔设置,并与ICC设备比较。
  • 临床研究:基于动物实验结果,在少量患者中实施EP。

主要发现

  • 切口力的主要影响因素是持续时间。
  • 凝血效果与效应和持续时间均相关。
  • endoCUT模式下knife-setting产生更高的切口力和更低的凝血效果。
  • 非放电凝血效果可能导致深溃疡。
  • 临床研究中未出现出血、胰腺炎或穿孔等显著不良事件。

关键数值与推荐

  • 理想ESU设置为「VIO EP模式」:knife-setting、高持续时间、最低效应、低间隔设置。

临床怎么用

  • EP时可考虑采用「VIO EP模式」(knife-setting、高持续时间、最低效应、低间隔)作为电外科设备设置参考。
  • 需注意非放电凝血效果可能导致深溃疡。

局限性

  • 临床研究样本量小(少量患者)。
  • 需更大规模临床研究积累数据并与ICC设备进行临床比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The optimal electrosurgical unit (ESU) settings for endoscopic papillectomy (EP) have not been investigated. We conducted animal experiments to determine the optimal endoCUT settings with VIO (Erbe, Tübingen, Germany) ESUs and then conducted a small clinical study. METHODS: Dedicated animal experimental models were created. To investigate the incision force, chicken meat was resected with a snare whose handle was a hung weight. To investigate the coagulation effect, a surgical needle electrode was inserted into a pig liver and energized, and to determine changes over time in the coagulation status, simulated EP was performed using a living pig. These experiments were performed using the knife-setting or snare-setting endoCUT modes and various effect, duration, and interval settings and compared with results for ICC (Erbe) ESUs. Based on the results, we performed EP in a small number of patients. RESULTS: The main factor affecting the incision force was duration. The coagulation effect was related to not only effect but also duration. In the endoCUT mode, knife-setting produced a higher incision force and lower coagulation effect. The nondischarge coagulation effect may cause deep ulceration. Based on the animal experiments, we concluded the ideal ESU setting for EP, "VIO EP mode," is knife-setting with high duration, lowest effect, and low interval settings. In the clinical study, there were no significant adverse events such as bleeding, pancreatitis, or perforation. CONCLUSIONS: "VIO EP mode" seems to afford optimal papillectomy. Larger scale clinical studies are needed to accumulate further data and make clinical comparisons with the ICC ESU.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Yamamoto K, Itoi T, Nagata N, et al. Optimal mode and power output of electrosurgical units for endoscopic papillectomy based on animal experiments and a preliminary clinical study (with videos). Gastrointest Endosc. 2021. PMID: 34678300. doi:10.1016/j.gie.2021.10.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。