深度学习计算机辅助息肉检测降低腺瘤漏诊率:美国多中心随机串联结肠镜研究
该研究为美国4家学术医学中心的前瞻性、多中心、单盲随机串联结肠镜试验,纳入232例筛查或监测患者,比较深度学习CADe系统与高清白光结肠镜。
要点
- CADe辅助结肠镜可显著降低腺瘤漏诊率(20.12% vs 31.25%)。
- CADe组无蒂锯齿状病变漏诊率低于HDWL组(7.14% vs 42.11%)。
- CADe组首次通过腺瘤检出数高于HDWL组(1.19 vs 0.90)。
核心结论
- 在美国多中心随机串联结肠镜试验中,与高清白光结肠镜相比,使用CADe系统可降低腺瘤漏诊率和无蒂锯齿状病变漏诊率,并提高首次通过腺瘤检出数。
研究设计与样本
- 前瞻性、多中心、单盲随机串联结肠镜研究,2019至2020年在美国4家学术医学中心纳入232例结直肠癌筛查或监测患者,随机分为CADe先行或HDWL先行,随后立即由同一内镜医师完成另一操作。
- 排除9例后,研究队列共223例;CADe先行组116例,HDWL先行组116例。
临床怎么用
- 在结直肠癌筛查或监测结肠镜中,可考虑使用深度学习CADe系统辅助检测息肉,以降低腺瘤及无蒂锯齿状病变漏诊风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Artificial intelligence-based computer-aided polyp detection (CADe) systems are intended to address the issue of missed polyps during colonoscopy. The effect of CADe during screening and surveillance colonoscopy has not previously been studied in a United States (U.S.) population. METHODS: We conducted a prospective, multi-center, single-blind randomized tandem colonoscopy study to evaluate a deep-learning based CADe system (EndoScreener, Shanghai Wision AI, China). Patients were enrolled across 4 U.S. academic medical centers from 2019 through 2020. Patients presenting for colorectal cancer screening or surveillance were randomized to CADe colonoscopy first or high-definition white light (HDWL) colonoscopy first, followed immediately by the other procedure in tandem fashion by the same endoscopist. The primary outcome was adenoma miss rate (AMR), and secondary outcomes included sessile serrated lesion (SSL) miss rate and adenomas per colonoscopy (APC). RESULTS: A total of 232 patients entered the study, with 116 patients randomized to undergo CADe colonoscopy first and 116 patients randomized to undergo HDWL colonoscopy first. After the exclusion of 9 patients, the study cohort included 223 patients. AMR was lower in the CADe-first group compared with the HDWL-first group (20.12% [34/169] vs 31.25% [45/144]; odds ratio [OR], 1.8048; 95% confidence interval [CI], 1.0780-3.0217; P = .0247). SSL miss rate was lower in the CADe-first group (7.14% [1/14]) vs the HDWL-first group (42.11% [8/19]; P = .0482). First-pass APC was higher in the CADe-first group (1.19 [standard deviation (SD), 2.03] vs 0.90 [SD, 1.55]; P = .0323). First-pass ADR was 50.44% in the CADe-first group and 43.64 % in the HDWL-first group (P = .3091). CONCLUSION: In this U.S. multicenter tandem colonoscopy randomized controlled trial, we demonstrate a decrease in AMR and SSL miss rate and an increase in first-pass APC with the use of a CADe-system when compared with HDWL colonoscopy alone.
引用
- Glissen Brown JR, Mansour NM, Wang P, et al. Deep Learning Computer-aided Polyp Detection Reduces Adenoma Miss Rate: A United States Multi-center Randomized Tandem Colonoscopy Study (CADeT-CS Trial). Clin Gastroenterol Hepatol. 2021. PMID: 34530161. doi:10.1016/j.cgh.2021.09.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。