短型单气囊小肠镜辅助ERCP在消化道改道术后患者中的疗效及操作结果影响因素:日本多中心队列研究
该多中心回顾性研究纳入日本8家三级转诊中心2011年9月至2019年8月间接受短型单气囊小肠镜(short SBE)辅助ERCP的1318例消化道改道术后患者,评估其疗效及操作结果影响因素。结果显示小肠镜到达目标部位成功率87.9%(95%CI 86.1%-89.6%),插管成功率87.0%(95%CI 84.9%-88.8%),总操作成功率74.9%(95%CI 72.5%-77.2%),不良事件发生率7.7%(95%CI 6.4%-9.3%)。多因素logistic回归分析表明年龄≥75岁、Roux-en-Y重建、胰腺指征及恶性肿瘤是总操作失败的影响因素。
要点
- 短型单气囊小肠镜辅助ERCP在消化道改道术后患者中总操作成功率为74.9%。
- 年龄≥75岁、Roux-en-Y重建、胰腺指征及恶性肿瘤与总操作失败相关。
- 不良事件发生率为7.7%,困难病例需熟练掌握替代治疗技术。
核心结论
- 这项大规模研究证明短型单气囊小肠镜辅助ERCP在消化道改道术后患者中是有效的,并明确了影响操作结果的因素。
研究设计与样本
- 多中心回顾性研究,在日本8家三级转诊中心开展,纳入2011年9月至2019年8月期间接受短型单气囊小肠镜辅助ERCP相关操作的1318例消化道改道术后患者。
主要发现
- 小肠镜到达目标部位成功率为87.9%(95%CI 86.1%-89.6%)。
- 插管成功率为87.0%(95%CI 84.9%-88.8%)。
- 总操作成功率为74.9%(95%CI 72.5%-77.2%)。
- 不良事件发生率为7.7%(95%CI 6.4%-9.3%)。
- 多因素logistic回归分析显示年龄≥75岁、Roux-en-Y重建、胰腺指征及恶性肿瘤是总操作失败的影响因素。
临床怎么用
- 对于消化道改道术后患者,短型单气囊小肠镜辅助ERCP可作为有效选择,但需注意年龄≥75岁、Roux-en-Y重建、胰腺指征及恶性肿瘤患者操作失败风险较高。
- 困难病例需熟练掌握替代治疗技术。
局限性
- 本研究为回顾性设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Although single-balloon enteroscopy (SBE)-assisted or short-type SBE (short SBE)-assisted ERCP has been reported as useful in patients with surgically altered anatomy, most studies had small sample sizes or single-center designs. This study aimed to evaluate the efficacy and factors affecting the procedure results of short SBE-assisted ERCP in patients with surgically altered anatomy. METHODS: This multicenter, retrospective study was conducted at 8 tertiary referral care centers in Japan. The data of patients who underwent ERCP-related procedures using short SBE between September 2011 and August 2019 at each facility were analyzed. RESULTS: Overall, 1318 patients were included in this analysis. The enteroscopy (reaching the target site), cannulation, and total procedural success rates were 87.9% (95% confidence interval [CI], 86.1%-89.6%), 87.0% (95% CI, 84.9%-88.8%), and 74.9% (95% CI, 72.5%-77.2%), respectively. Adverse events occurred in 7.7% of patients (95% CI, 6.4%-9.3%). Multiple logistic regression analysis indicated that age (≥75 years), Roux-en-Y reconstruction, pancreatic indication, and malignancy were factors affecting the total procedural failure. CONCLUSIONS: This large-scale study proved that short SBE-assisted ERCP in patients with surgically altered anatomy was effective. Moreover, it clarified factors affecting procedure results. Proficiency with alternative treatment techniques is required in difficult cases. (Clinical trial registration number: UMIN00004045.).