新型电灼增强腔镜金属支架在介入EUS中的安全性与疗效
BACKGROUND AND AIMS: Electrocautery-tip lumen-apposing metal stents (EC-LAMSs) have extended the indications of therapeutic EUS.…
要点
- Hot-Spaxus新型EC-LAMS在多种介入EUS适应症中技术成功率高。
- 结局与现有Hot-Axios EC-LAMS对照组相似。
核心结论
- 新型EC-LAMS在多种介入EUS适应症中具有较高的技术和临床成功率。
主要发现
- 58例患者中男性36例、女性22例,平均年龄63.5±14.9岁。
- 不良事件6例(11.1%):早期2例(3.7%)、晚期1例(1.8%)、长期3例(5.6%)。
- 结局与Hot-Axios对照组相似。
临床怎么用
- 该新型EC-LAMS可用于胰腺液体积聚引流、恶性远端胆道梗阻引流等多种介入EUS适应症。
局限性
- 回顾性设计,样本量58例,需未来多中心前瞻性研究进一步明确不同适应症中的作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Electrocautery-tip lumen-apposing metal stents (EC-LAMSs) have extended the indications of therapeutic EUS. We aimed to retrospectively evaluate safety and technical and clinical success of a newly developed EC-LAMS, the Hot-Spaxus (Taewoong Medical Co, Gimpo, Korea), for various EUS-guided procedures. METHODS: We included and retrospectively analyzed consecutive patients at 8 tertiary care referral centers who had undergone EUS interventional procedures using the Hot-Spaxus between October 2018 and February 2021. RESULTS: Of 58 included patients (male-to-female, 36:22; mean age, 63.5 ± 14.9 years), 29 had undergone pancreatic fluid collection drainage (50%), 22 (37.9%) biliary drainage for malignant distal obstruction, 3 (5.1%) gallbladder drainage for acute cholecystitis, 3 gastroenteroanastomoses, and 1 (1.7%) pelvic collection drainage. Technical success was achieved in 54 of 58 patients (93.1%) and clinical success in all 58. Adverse events occurred in 6 patients (11.1%): 2 early (3.7%), 1 late (1.8%), and 3 long term (5.6%). The outcomes were similar to those observed in a control group of patients treated with the Hot-Axios (Boston Scientific, Marlborough, Mass, USA), the other available EC-LAMS. CONCLUSIONS: Our study showed that the novel EC-LAMS has high technical and clinical success rates for various interventional EUS indications. Future multicenter prospective studies will better clarify the role of this new EC-LAMS for different indications.
引用
- Mangiavillano B, Moon JH, Crinò SF, et al. Safety and efficacy of a novel electrocautery-enhanced lumen-apposing metal stent in interventional EUS procedures (with video). Gastrointest Endosc. 2021. PMID: 34339667. doi:10.1016/j.gie.2021.07.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。