巴雷特食管三维自动量化用于风险分层与治疗监测的初步研究
本研究提出一种基于深度学习的人工智能系统,可自动测量巴雷特食管的布拉格C&M评分、巴雷特上皮面积及岛状病变,并实现食管表面三维重建。系统在体模视频上对C&M和岛状测量准确率达97.2%,对上皮面积准确率达98.4%;在131例患者的194段高清视频中,C与M评分与专家评分的平均相对误差分别为8%和7%。
要点
- AI系统自动测量布拉格C&M评分,体模准确率97.2%,患者数据平均相对误差8%和7%
- 可量化巴雷特上皮总面积及岛状病变,体模面积准确率98.4%
- 支持食管表面三维重建,为风险分层和治疗反应评估提供新工具
核心结论
- 所提出的方法能高精度自动提取布拉格C&M评分,并实现巴雷特上皮面积量化与三维重建。
研究设计与样本
- 采用深度学习深度估计网络预测内镜镜头至胃皱襞距离,分割巴雷特上皮与胃食管交界并投影至毫米距离以计算C&M评分。
- 在定制3D打印食管体模和来自131例患者的194段高清视频上验证,C&M值由专家内镜医师评分。
主要发现
- 体模内镜视频数据中,C&M及岛状测量准确率97.2%,平均偏差±0.9 mm。
- 体模中巴雷特上皮面积测量准确率98.4%,平均偏差仅±0.4 cm²。
- 患者数据中,系统C评分与专家评分平均相对误差8%(3.6 mm),M评分平均相对误差7%(2.8 mm)。
临床怎么用
- 该系统可自动、客观地量化巴雷特食管范围与面积,减少布拉格C&M评分对操作者的依赖。
- 三维重建与面积量化有助于风险分层及治疗反应监测。
局限性
- 原文未明确报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Barrett's epithelium measurement using widely accepted Prague C&M classification is highly operator dependent. We propose a novel methodology for measuring this risk score automatically. The method also enables quantification of the area of Barrett's epithelium (BEA) and islands, which was not possible before. Furthermore, it allows 3-dimensional (3D) reconstruction of the esophageal surface, enabling interactive 3D visualization. We aimed to assess the accuracy of the proposed artificial intelligence system on both phantom and endoscopic patient data. METHODS: Using advanced deep learning, a depth estimator network is used to predict endoscope camera distance from the gastric folds. By segmenting BEA and gastroesophageal junction and projecting them to the estimated mm distances, we measure C&M scores including the BEA. The derived endoscopy artificial intelligence system was tested on a purpose-built 3D printed esophagus phantom with varying BEAs and on 194 high-definition videos from 131 patients with C&M values scored by expert endoscopists. RESULTS: Endoscopic phantom video data demonstrated a 97.2% accuracy with a marginal ± 0.9 mm average deviation for C&M and island measurements, while for BEA we achieved 98.4% accuracy with only ±0.4 cm2 average deviation compared with ground-truth. On patient data, the C&M measurements provided by our system concurred with expert scores with marginal overall relative error (mean difference) of 8% (3.6 mm) and 7% (2.8 mm) for C and M scores, respectively. CONCLUSIONS: The proposed methodology automatically extracts Prague C&M scores with high accuracy. Quantification and 3D reconstruction of the entire Barrett's area provides new opportunities for risk stratification and assessment of therapy response.
引用
- Ali S, Bailey A, Ash S, et al. A Pilot Study on Automatic Three-Dimensional Quantification of Barrett's Esophagus for Risk Stratification and Therapy Monitoring. Gastroenterology. 2021. PMID: 34116029. doi:10.1053/j.gastro.2021.05.059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。