文献速递消化内镜消化道肿瘤与早癌

联动彩色成像联合黏膜暴露装置与标准结肠镜腺瘤检出随机试验

Linked color imaging, mucosal exposure device, their combination, and standard colonoscopy for adenoma detection: a randomized trial.
PubMed 文献 · Gastrointest Endosc · 2021-05-31

结果显示LCI+EAC组ADR和近端ADR最高,但多重比较校正后仅LCI+EAC与标准高清结肠镜的近端ADR差异显著,腺瘤数目比率在联合组及两个单用组均显著高于标准组。

要点

  • LCI联合EAC组ADR为57.2%,标准高清结肠镜组为47.6%。
  • 校正后仅LCI+EAC与标准高清结肠镜的近端ADR差异显著。
  • LCI+EAC、LCI、EAC组腺瘤数目比率均显著高于标准高清结肠镜组。

核心结论

  • 由高腺瘤检出率操作者实施时,LCI联合EAC可显著改善近端腺瘤检出率和每次结肠镜平均腺瘤数,但未显著改善总体腺瘤检出率。

研究设计与样本

  • 所有结肠镜检查由记录腺瘤检出率≥35%的内镜医师完成。

主要发现

  • LCI+EAC、LCI、EAC和标准高清结肠镜组的腺瘤检出率分别为57.2%、52.8%、51.6%和47.6%。
  • 上述四组的近端腺瘤检出率分别为38.4%、34.8%、33.6%和28.0%。

临床怎么用

  • 在高腺瘤检出率操作者中,可考虑采用LCI联合EAC以提高近端腺瘤检出率和每次结肠镜平均腺瘤数。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: By different mechanisms, image-enhancement techniques (linked color imaging [LCI]) and mucosal exposure devices (Endocuff-assisted colonoscopy [EAC]) can improve the adenoma detection rate (ADR) during screening colonoscopy. The impact of the combination of the 2 techniques has never been studied. This study aimed to compare the ADR between the combination of LCI and EAC (LCI+EAC), LCI alone, EAC alone, and standard high-definition (HD) colonoscopy. METHODS: This prospective randomized controlled trial included participants who underwent screening colonoscopy. Participants were randomized to LCI+EAC, LCI, EAC, and standard HD colonoscopy. All colonoscopies were performed by endoscopists with a recorded ADR ≥35%. The primary outcome was the ADR. Secondary outcomes were proximal ADR (pADR) and the mean number of adenomas per colonoscopy (APC). RESULTS: One thousand participants were included in the study. The LCI+EAC group provided the highest ADR and pADR. The ADRs in the LCI+EAC, LCI, EAC, and standard HD colonoscopy groups were 57.2%, 52.8%, 51.6%, and 47.6%, respectively, with pADRs of 38.4%, 34.8%, 33.6%, and 28.0%, respectively. The mean numbers of APC were 1.28, 1.20, 1.16, and .89, respectively. After a multiple comparison adjustment, a significant difference in pADR was only observed between the LCI+EAC and standard HD colonoscopy groups (difference, 10.3 percentage points; 95% confidence interval, .02%-17.4%; P = .05). The incidence rate ratios of the adenoma numbers were significantly higher in the LCI+EAC (1.43), LCI (1.34), and EAC (1.30) groups relative to the standard HD colonoscopy group (.89) (P < .009 for all comparisons). CONCLUSIONS: The combination of LCI and EAC can significantly improve the detection of pADR and APC but not ADR by high-ADR performers. (Clinical trial registration number: TCTR20190319001.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Aniwan S, Vanduangden K, Kerr SJ, et al. Linked color imaging, mucosal exposure device, their combination, and standard colonoscopy for adenoma detection: a randomized trial. Gastrointest Endosc. 2021. PMID: 34081966. doi:10.1016/j.gie.2021.05.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。