营养饮水试验作为功能性消化不良的生物标志物

Nutrient Drinking Test as Biomarker in Functional Dyspepsia.
PubMed 文献 · Am J Gastroenterol · 2021-01-01

本文综述了不同饮水试验(DT)作为功能性消化不良(FD)胃感觉运动功能障碍生物标志物的潜力。通过PubMed和MEDLINE检索相关文献,发现FD患者在不同DT中摄入量显著减少,其中缓慢营养饮水(饱腹感饮水)试验(SDT)在区分健康与FD及与胃容受性(GA)相关性方面最为一致。SDT是反映GA的潜在诊断生物标志物,但需进一步研究确认其预测治疗结局的作用。

要点

  • 缓慢营养饮水试验(SDT)与胃容受性(GA)相关,能较好区分健康与FD。
  • FD患者在不同饮水试验中摄入量均显著减少。
  • SDT可评估药物对GA和耐受容积的影响,但中枢作用药物无此相关。

核心结论

  • SDT是反映胃容受性的潜在诊断生物标志物,但预测治疗结局的作用需进一步研究确认。

研究设计与样本

  • 通过PubMed和MEDLINE检索英文文献,包括综述、荟萃分析、病例系列、随机对照试验及会议摘要。

主要发现

  • FD患者在不同饮水试验变体中摄入量显著减少。
  • 缓慢营养饮水试验(SDT)在区分健康与FD及与胃容受性(GA)相关性方面最为一致。
  • 对扩张的敏感性可能与快速饮水试验相关。
  • SDT用于评估药物对GA和耐受营养容积的影响,常显示两者一致,但主要对中枢作用药物未发现此相关性。

临床怎么用

  • SDT可作为FD患者胃容受性评估的潜在诊断工具。

局限性

  • 需额外研究确认SDT作为FD治疗结局预测生物标志物的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Functional dyspepsia (FD) is a prevalent condition with multifactorial pathophysiology, including impaired gastric accommodation (GA), hypersensitivity to gastric distention, and delayed gastric emptying. Drink tests (DT) have been proposed as a potential biomarker for the presence and severity of gastric sensorimotor dysfunction. Thus, we aimed to summarize the state of knowledge on different DT and their potential as a biomarker for FD. METHODS: A PubMed and MEDLINE search was conducted for English language articles, reviews, meta-analyses, case series, and randomized controlled trials, including also published meeting abstracts. RESULTS: Several DT have been described in literature (e.g., different type of liquid, number of calories used, pace of drinking, and subject's awareness of the amount of liquid drunk). FD patients ingest significantly less volume in the different variants of the tests. The slow nutrient ("satiety drinking") test (SDT) studies show the most consistent separation between health and FD and correlation with GA. However, sensitivity to distention may be correlated with rapid DT. SDTs were used to evaluate the effect of several pharmacological agents, often showing concordance between their effects on GA and tolerated nutrient volume. This correlation was not found mainly for agents with central actions. DISCUSSION: An SDT is a potential diagnostic biomarker in FD, reflecting GA. Additional studies are required to confirm its role as a predictive biomarker for treatment outcome in FD.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Scarpellini E, Van den Houte K, Schol J, et al. Nutrient Drinking Test as Biomarker in Functional Dyspepsia. Am J Gastroenterol. 2021. PMID: 33941747. doi:10.14309/ajg.0000000000001242

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。