联动彩色成像检测结直肠肿瘤:前瞻性随机串联结肠镜试验
这项前瞻性随机串联结肠镜试验将780例患者随机分组,最终分析700例,比较联动彩色成像(LCI)与白光成像(WLI)对结直肠肿瘤的检出效果。结果显示两组腺瘤检出率(ADR)无显著差异,但LCI组腺瘤漏诊率(AMR)显著低于WLI组,尤其在微小腺瘤和非息肉样病变中。LCI可能使低ADR的内镜医师获益。
要点
- LCI与WLI的ADR无显著差异(69.6% vs 63.2%)。
- LCI组总AMR显著低于WLI组(20.6% vs 31.1%,P < .001)。
- LCI对微小腺瘤和非息肉样病变的AMR改善更明显。
核心结论
- LCI与WLI的ADR相似,但LCI的腺瘤漏诊率更低。
- LCI可能使低ADR的内镜医师获益,需进一步研究。
研究设计与样本
- 前瞻性、随机、串联结肠镜试验,共780例患者随机分组,700例纳入最终分析。
- 分组为首次LCI后第二次WLI(LCI组)或两次均WLI(WLI组)。
主要发现
- LCI组与WLI组首次观察的ADR分别为69.6%和63.2%,无显著差异。
- LCI组总AMR为20.6%,显著低于WLI组的31.1%(P < .001)。
- LCI组微小腺瘤AMR为23.4%,显著低于WLI组的35.1%(P < .001)。
- LCI组非息肉样病变AMR为25.6%,显著低于WLI组的37.9%(P < .001)。
- LCI在低检出者中平均ADR为76.0%,高于高检出者的55.1%(P < .001)。
临床怎么用
- LCI可作为降低腺瘤漏诊的成像选择,尤其对低ADR内镜医师。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: A higher adenoma detection rate (ADR) has been shown to be related to a lower incidence and mortality of colorectal cancer. We analyzed the efficacy of linked color imaging (LCI) by assessing the detection, miss, and visibility of various featured adenomas as compared with white light imaging (WLI). METHODS: This was a prospective, randomized, tandem trial. The participants were randomly assigned to 2 groups: first observation by LCI, then second observation by WLI (LCI group); or both observations by WLI (WLI group). Suspected neoplastic lesions were resected after magnifying image-enhanced endoscopy. The primary outcome was to compare the ADR during the first observation. Secondary outcomes included evaluation of adenoma miss rate (AMR) and visibility score. RESULTS: A total of 780 patients were randomized, 700 of whom were included in the final analysis. The ADR was 69.6% and 63.2% in the LCI and WLI groups, respectively, with no significant difference. However, LCI improved the average ADR in low-detectors compared with high-detectors (76.0% vs 55.1%; P < .001). Total AMR was 20.6% in the LCI group, which was significantly lower than that in the WLI group (31.1%) (P < .001). AMR in the LCI group was significantly lower, especially for diminutive adenomas (23.4% vs 35.1%; P < .001) and nonpolypoid lesions (25.6% vs 37.9%; P < .001) compared with the WLI group. CONCLUSION: Although both methods provided a similar ADR, LCI had a lower AMR than WLI. LCI could benefit endoscopists with lower ADR, an observation that warrants additional study. (UMIN Clinical Trials Registry, Number: UMIN000026359).
引用
- Hasegawa I, Yamamura T, Suzuki H, et al. Detection of Colorectal Neoplasms Using Linked Color Imaging: A Prospective, Randomized, Tandem Colonoscopy Trial. Clin Gastroenterol Hepatol. 2021. PMID: 33839277. doi:10.1016/j.cgh.2021.04.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。