文献速递肝病

超声与磁共振弹性成像对非酒精性脂肪性肝病肝纤维化分期的直接比较

Direct Comparison of US and MR Elastography for Staging Liver Fibrosis in Patients With Nonalcoholic Fatty Liver Disease.
PubMed 文献 · Clin Gastroenterol Hepatol · 2020-12-17

该研究纳入231例经活检证实为非酒精性脂肪性肝病的患者,直接比较磁共振弹性成像、振动控制瞬时弹性成像和二维剪切波弹性成像的诊断能力。三种方法检测各期纤维化的曲线下面积无差异,但磁共振弹性成像对4期纤维化的诊断准确率及观察者内和观察者间可重复性最高。

要点

  • 磁共振弹性成像对4期纤维化的诊断准确率高于振动控制瞬时弹性成像和二维剪切波弹性成像。
  • 磁共振弹性成像的观察者内和观察者间可重复性优于振动控制瞬时弹性成像和二维剪切波弹性成像。
  • 性别是振动控制瞬时弹性成像与纤维化分期不一致的显著预测因素。

核心结论

  • 磁共振弹性成像、振动控制瞬时弹性成像和二维剪切波弹性成像在检测非酒精性脂肪性肝病患者肝纤维化方面均表现出极好的诊断准确率。
  • 磁共振弹性成像对4期纤维化检测的诊断准确率及观察者内和观察者间可重复性最高。

研究设计与样本

  • 研究纳入231例经活检证实为非酒精性脂肪性肝病的患者。
  • 在70例参与者亚组中,由一名弹性成像专家和一名弹性成像受训的超声专家在同一天进行肝硬度测量,使用组内相关系数分析观察者内和观察者间可重复性。

主要发现

  • 磁共振弹性成像、振动控制瞬时弹性成像、二维剪切波弹性成像及三者联合分别有227、220、204和201例患者获得有效肝硬度测量。
  • 检测≥1期、≥2期和≥3期肝纤维化时,各方法间曲线下面积无差异;检测4期时,磁共振弹性成像的曲线下面积高于振动控制瞬时弹性成像和二维剪切波弹性成像。
  • 性别是振动控制瞬时弹性成像与肝纤维化分期不一致的显著预测因素。
  • 皮肤到肝包膜距离及肝硬度四分位间距与中位数的比值与二维剪切波弹性成像和肝纤维化分期不一致显著相关。
  • 无因素与磁共振弹性成像和肝纤维化分期不一致相关。

关键数值与推荐

  • 磁共振弹性成像检测肝纤维化的观察者内和观察者间可重复性高于振动控制瞬时弹性成像和二维剪切波弹性成像。

临床怎么用

  • 在非酒精性脂肪性肝病患者中,磁共振弹性成像、振动控制瞬时弹性成像和二维剪切波弹性成像均可用于肝纤维化检测。
  • 当需要最高诊断准确率(尤其是4期纤维化)和可重复性时,磁共振弹性成像可能更优。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: As alternatives to the expensive liver biopsy for assessing liver fibrosis stage in patients with nonalcoholic fatty liver disease (NAFLD), we directly compared the diagnostic abilities of magnetic resonance elastography (MRE), vibration-controlled transient elastography (VCTE), and two-dimensional shear wave elastography (2D-SWE). METHODS: Overall, 231 patients with biopsy-proven NAFLD were included. Intra- and inter-observer reproducibility was analyzed using intraclass correlation coefficient in a sub-group of 70 participants, in whom liver stiffness measurement (LSM) was performed by an elastography expert and an ultrasound expert who was an elastography trainee on the same day. RESULTS: Valid LSMs were obtained for 227, 220, 204, and 201 patients using MRE, VCTE, 2D-SWE, and all three modalities combined, respectively. Although the area under the curve did not differ between the modalities for detecting stage ≥1, ≥2, and ≥3 liver fibrosis, it was higher for MRE than VCTE and 2D-SWE for stage 4. Sex was a significant predictor of discordance between VCTE and liver fibrosis stage. Skin-capsule distance and the ratio of the interquartile range of liver stiffness to the median were significantly associated with discordance between 2D-SWE and liver fibrosis stage. However, no factors were associated with discordance between MRE and liver fibrosis stage. Intra- and inter-observer reproducibility in detecting liver fibrosis was higher for MRE than VCTE and 2D-SWE. CONCLUSIONS: MRE, VCTE, and 2D-SWE demonstrated excellent diagnostic accuracy in detecting liver fibrosis in patients with NAFLD. MRE demonstrated the highest diagnostic accuracy for stage 4 detection and intra- and inter-observer reproducibility. UMIN Clinical Trials Registry No. UMIN000031491.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Imajo K, Honda Y, Kobayashi T, et al. Direct Comparison of US and MR Elastography for Staging Liver Fibrosis in Patients With Nonalcoholic Fatty Liver Disease. Clin Gastroenterol Hepatol. 2020. PMID: 33340780. doi:10.1016/j.cgh.2020.12.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。