二维剪切波弹性成像可靠性标准:788例患者4277次测量分析
该研究基于788例慢性肝病患者的肝活检与二维剪切波弹性成像(2D-SWE)检查,将4277次测量按2:1随机分为推导集与验证集,推导出基于硬度值和变异系数的可靠性标准,并发现三次可靠测量可获得最佳诊断准确性。
要点
- 2D-SWE测量可靠性取决于肝硬度水平和变异系数(CV)。
- 新标准:硬度<8.8 kPa,或8.8-11.9 kPa且CV<0.25,或≥12.0 kPa且CV<0.10。
- 一次2D-SWE检查应包含三次可靠测量以获得最佳诊断准确性。
核心结论
- 2D-SWE测量的可靠性依赖于变异系数和肝硬度水平,一次检查应包含三次符合新标准的可靠测量。
研究设计与样本
- 多中心研究,纳入788例慢性肝病患者,均接受肝活检和2D-SWE检查,共4277次测量按2:1随机分为推导集(n=2851)和验证集(n=1426)。
主要发现
- 全部4277次测量中,桥接纤维化AUROC为0.825±0.006,肝硬化AUROC为0.880±0.006。
- 平均硬度和变异系数是桥接纤维化或肝硬化的独立预测因素。
- 三次可靠测量可获得最佳诊断准确性。
关键数值与推荐
- 可靠2D-SWE测量标准:硬度<8.8 kPa,或硬度8.8-11.9 kPa且CV<0.25,或硬度≥12.0 kPa且CV<0.10。
临床怎么用
- 临床解读2D-SWE结果时应结合硬度值和变异系数判断测量可靠性。
- 建议每次2D-SWE检查获取三次符合新标准的可靠测量以提高诊断准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Two-dimensional shear wave elastography (2D-SWE) is an accurate method for the non-invasive evaluation of liver fibrosis. We aimed to determine the reliability criteria and the number of necessary reliable measurements for 2D-SWE. METHODS: 788 patients with chronic liver disease underwent liver biopsy and 2D-SWE examination in three centers. The 4277 2D-SWE measurements performed were 2:1 randomly divided into derivation (n = 2851) and validation (n = 1426) sets. Reliability criteria for a 2D-SWE measurement were defined in the derivation set from the intrinsic characteristics given by the device (mean liver stiffness, standard deviation, diameter of the region of interest), with further evaluation in the validation set. RESULTS: In the whole population of 4277 measurements, AUROC for bridging fibrosis was 0.825 ± 0.006 and AUROC for cirrhosis was 0.880 ± 0.006. Mean stiffness and coefficient of variation (CV) were independent predictors of bridging fibrosis or cirrhosis. From these two parameters, new criteria were derived to define a reliable 2D-SWE measurement: stiffness <8.8 kPa, or stiffness between 8.8-11.9 kPa with CV <0.25, or stiffness ≥12.0 kPa with CV <0.10. In the validation set, AUROC for bridging fibrosis was 0.830 ± 0.013 in reliable measurements vs 0.667 ± 0.031 in unreliable measurements (P < .001). AUROC for cirrhosis was 0.918±0.014 vs 0.714 ± 0.027, respectively (P < .001). The best diagnostic accuracy for a 2D-SWE examination was achieved from three reliable measurements. CONCLUSIONS: Reliability of a 2D-SWE measurement relies on the coefficient of variation and the liver stiffness level. A 2D-SWE examination should include three reliable measurements according to our new criteria.
引用
- Paisant A, Lemoine S, Cassinotto C, et al. Reliability Criteria of Two-Dimensional Shear Wave Elastography: Analysis of 4277 Measurements in 788 Patients. Clin Gastroenterol Hepatol. 2020. PMID: 33340779. doi:10.1016/j.cgh.2020.12.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。