瞬时与二维剪切波弹性成像在NAFLD进展性纤维化多步诊断策略中的比较
本研究回顾性纳入577例疑似NAFLD患者,比较FIB-4联合VCTE或2D-SWE-SSI两步策略及三步策略诊断进展性纤维化(F≥3)的性能。2D-SWE-SSI与VCTE准确性相当,但2D-SWE-SSI需肝活检者更多;三步策略显著减少肝活检需求并保持准确性。
要点
- 2D-SWE-SSI诊断进展性纤维化的准确性不劣于VCTE。
- FIB-4/2D-SWE-SSI策略需肝活检比例高于FIB-4/VCTE策略。
- 三步策略可显著降低肝活检需求并保持高准确性。
核心结论
- 在相同截断值下,2D-SWE-SSI诊断NAFLD进展性肝纤维化的准确性与VCTE相当。
- 对部分患者采用三步策略可大幅减少肝活检需求,同时保持优异的诊断准确性。
研究设计与样本
- 从前瞻性登记库中回顾性选取577例疑似NAFLD的连续患者。
- 所有患者均接受实验室检查计算FIB-4、VCTE(M和XL探头)和2D-SWE-SSI评估肝硬度,以及肝活检。
主要发现
- FIB-4、VCTE和2D-SWE-SSI的曲线下面积分别为0.74、0.82和0.88。
- FIB-4/2D-SWE-SSI与FIB-4/VCTE诊断性能相当:敏感性71.4%和66%、特异性91.4%和91.5%、准确性83.7%和81.4%(所有P=无显著性)。
- 2D-SWE-SSI后需肝活检的患者比例高于VCTE(24.6%对15.3%,P<0.001)。
- 对结果不可靠或处于灰区(8-10 kPa)的患者进行第二种弹性成像技术,肝活检需求大幅降至42/577(7.3%)。
- FIB-4/2D-SWE-SSI/VCTE与FIB-4/VCTE/2D-SWE-SSI的诊断性能相当:准确性81.1%对81.3%、敏感性71.5%对69.7%、特异性87.9%对89.5%(所有P=无显著性)。
关键数值与推荐
- 进展性纤维化定义为F≥3。
- 灰区定义为弹性成像结果在8至10 kPa之间。
- FIB-4、VCTE和2D-SWE-SSI的AUC分别为0.74、0.82和0.88。
临床怎么用
- 在NAFLD进展性纤维化诊断中,2D-SWE-SSI可作为VCTE的替代弹性成像方法。
- 对弹性成像结果不可靠或处于灰区的患者,加做第二种弹性成像技术可显著减少肝活检。
局限性
- 回顾性研究设计。
- 来自单一前瞻性登记库,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: The combination of laboratory and elastography tests allows the accurate diagnosis of advanced liver fibrosis in patients with NAFLD. In this study, we compared the diagnostic performances of a two-step strategy (laboratory tests and vibration-controlled transient elastography [VCTE] or two-dimensional shear-wave elastography with SuperSonic Imagine [2D-SWE-SSI]) and the added value of a three-step strategy (laboratory tests and two elastography methods). APPROACH AND RESULTS: From a prospective registry, we retrospectively selected 577 consecutive patients with suspicion of NAFLD who underwent laboratory tests to calculate the Fibrosis-4 (FIB-4) score, liver stiffness evaluation by VCTE (M and XL probes) and 2D-SWE-SSI, and liver biopsy. The diagnostic performances and need for liver biopsy in unclassified patients for the diagnosis of advanced fibrosis (F ≥ 3) in multistep strategies were compared. The area under the curve of FIB-4, VCTE, and 2D-SWE-SSI was 0.74, 0.82, and 0.88, respectively. Using the same thresholds, the FIB-4/2D-SWE-SSI and FIB-4/VCTE diagnostic performances were comparable (sensitivity, 71.4% and 66%; specificity, 91.4% and 91.5%; and accuracy, 83.7% and 81.4%; all P = not significant). Conversely, more patients required liver biopsy after 2D-SWE-SSI (24.6% versus 15.3%, P < 0.001). Performing a second elastography technique in patients with unreliable or gray zone (between 8 and 10 kPa) results greatly decreased the need for liver biopsy (42/577, 7.3%). The diagnostic performances (accuracy, sensitivity, and specificity) of FIB-4/2D-SWE-SSI/VCTE and FIB-4/VCTE/2D-SWE-SSI were comparable (81.1%, 71.5%, and 87.9% versus 81.3%, 69.7%, and 89.5%, respectively; all P = not significant). CONCLUSIONS: Using the same cutoff values, 2D-SWE-SSI is as accurate as VCTE for advanced liver fibrosis diagnosis in NAFLD. The three-step strategy in selected patients strongly decreased the need for liver biopsy while maintaining excellent accuracy.
引用
- Cassinotto C, Boursier J, Paisant A, et al. Transient Versus Two-Dimensional Shear-Wave Elastography in a Multistep Strategy to Detect Advanced Fibrosis in NAFLD. Hepatology. 2021. PMID: 33236409. doi:10.1002/hep.31655
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。