第二代远端附加帽装置提高腺瘤检出率:随机对照试验的荟萃分析
该系统综述与荟萃分析纳入8项随机对照试验共5695例患者,比较第二代远端附加帽结肠镜(CC组2862例)与标准高清结肠镜(SC组2833例)。结果显示CC组腺瘤检出率显著高于SC组(49.8% vs 45.6%,RR 1.12,P=0.02),息肉检出率、每次结肠镜平均腺瘤数亦改善,且平均退镜时间缩短0.93分钟。
要点
- 第二代远端附加帽结肠镜较标准结肠镜显著提高腺瘤检出率(49.8% vs 45.6%,RR 1.12,P=0.02)。
- 息肉检出率(58.1% vs 53%,RR 1.12,P=0.009)和每次结肠镜平均腺瘤数(P<0.01)亦显著改善。
- 平均退镜时间较标准结肠镜缩短0.93分钟(P<0.01)。
核心结论
- 随机试验的荟萃分析结果显示,与标准结肠镜相比,使用第二代远端附加帽装置可显著改善腺瘤检出率和每次结肠镜平均腺瘤数,且退镜时间更短。
研究设计与样本
- 系统综述与荟萃分析,检索PubMed、Google Scholar、Embase和Cochrane Library截至2020年5月,纳入8项随机对照试验共5695例患者。
- 第二代远端附加帽结肠镜组2862例(平均年龄62.8岁,男性52.9%),标准结肠镜组2833例(平均年龄62.6岁,男性54.2%)。
主要发现
- 腺瘤检出率:CC组49.8% vs SC组45.6%(RR 1.12,P=0.02)。
- 息肉检出率:CC组58.1% vs SC组53%(RR 1.12,P=0.009)。
- 每次结肠镜平均腺瘤数:CC组较SC组改善(P<0.01)。
- 平均退镜时间:CC组较SC组缩短0.93分钟(P<0.01)。
- 腺瘤检出率差异在筛查/监测人群(6.5%,P=0.02)和腺瘤检出率<30%的内镜医师使用时(9.4%,P=0.03)更大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Multiple randomized controlled trials (RCTs) using the second-generation distal attachment cuff device (Endocuff Vision; Olympus America, Center Valley, Pa, USA) have reported conflicting results in improving adenoma detection rate (ADR) compared with standard high-definition colonoscopy without the distal attachment. We conducted a systematic review and meta-analysis of RCTs to compare outcomes between second-generation cuff colonoscopy (CC) versus colonoscopy without the distal attachment (standard colonoscopy [SC]). METHODS: An electronic literature search was performed using PubMed, Google Scholar, Embase, and Cochrane Library through May 2020. The primary outcome was reporting of ADR, and secondary outcomes were polyp detection rate (PDR), mean withdrawal time, mean adenomas per colonoscopy (APC), sessile serrated lesion detection rate, and adverse events. Pooled rates and risk ratios (RRs) with 95% confidence intervals were reported. RESULTS: Eight RCTs with 5695 patients were included in the final analysis, with 2862 patients (mean age, 62.8 years; 52.9% men) in the CC group and 2833 patients (mean age, 62.6 years; 54.2% men) in the SC group. Compared with SC, use of CC was associated with a significant improvement in ADR (49.8% vs 45.6%, respectively; RR, 1.12; P = .02), PDR (58.1% vs 53%, respectively; RR, 1.12; P = .009), and APC (P < .01). Furthermore, use of CC had a .93-minute lower mean withdrawal time (P < .01) when compared with SC. The difference in ADR was larger in the screening/surveillance population (6.5%, P = .02) and when used by endoscopists with ADRs <30% (9.4%, P = .03). CONCLUSIONS: The results of this meta-analysis of randomized trials show a significant improvement in ADR and APC with shorter withdrawal times using the second-generation cuff device compared with SC.
引用
- Patel HK, Chandrasekar VT, Srinivasan S, et al. Second-generation distal attachment cuff improves adenoma detection rate: meta-analysis of randomized controlled trials. Gastrointest Endosc. 2020. PMID: 33031786. doi:10.1016/j.gie.2020.09.045