文献速递消化内镜消化道肿瘤与早癌

使用多功能圈套器行结直肠内镜黏膜下剥离术的前瞻性临床可行性研究(附视频)

Evaluation of colorectal endoscopic submucosal dissection using a multifunctional snare: a prospective clinical feasibility study (with videos).
PubMed 文献 · Gastrointest Endosc · 2020-09-18

这项前瞻性先导性临床可行性研究于2018年10月至2019年1月在两家中心纳入119例连续患者(121例次ESD、137个结直肠肿瘤),评估使用SOUTEN圈套器行结直肠ESD的安全性和有效性。结果显示全部病例均完成SOUTEN-ESD,整块切除率和R0切除率均为100%,穿孔率0%,迟发出血率2.2%,ESD后凝血综合征发生率2.9%。作者认为SOUTEN-ESD安全且结局良好,但需进一步研究明确适应证并验证结果。

要点

  • 137个结直肠肿瘤均完成SOUTEN-ESD,无需转为混合ESD或专用ESD器械。
  • 整块切除率和R0切除率均为100%,穿孔率0%,迟发出血率2.2%。
  • 作者认为SOUTEN圈套器是结直肠ESD的现实选择,但需进一步研究。

核心结论

  • SOUTEN-ESD安全且结局良好。
  • 作者认为尽管需进一步研究明确SOUTEN-ESD的适应证并验证本研究结果,但使用这种新型刀进行有效ESD是可行的。
  • 作者认为SOUTEN圈套器是结直肠ESD的现实选择。

研究设计与样本

  • 前瞻性、先导性、临床可行性研究。
  • 2018年10月至2019年1月在NTT Medical Center Tokyo和Omori Red Cross Hospital前瞻性纳入119例连续患者(121例次ESD、137个结直肠肿瘤)并接受SOUTEN-ESD治疗。
  • 评估SOUTEN-ESD的结局。
  • 临床试验注册号:UMIN 000034299。

主要发现

  • 137个肿瘤中,SOUTEN-ESD全部完成。
  • 无病例需转为混合ESD或转为专用ESD器械。
  • 平均手术时间为26.1 ± 14.3分钟。
  • 整块切除率和R0切除率均为100%。
  • 穿孔率为0%,迟发出血率为2.2%,ESD后凝血综合征发生率为2.9%。

关键数值与推荐

  • 整块切除率100%,R0切除率100%。
  • 穿孔率0%,迟发出血率2.2%,ESD后凝血综合征发生率2.9%。
  • 平均手术时间26.1 ± 14.3分钟。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需进一步研究以明确SOUTEN-ESD的适应证并验证本研究结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The number of colorectal endoscopic submucosal dissections (ESDs) for early colorectal cancer is expected to increase in the future; therefore, cost reduction is a clinically important issue. The SOUTEN snare (Kaneka Medics, Tokyo, Japan) is a novel multifunctional snare developed for hybrid ESD at a low price. If ESD can be performed safely using the SOUTEN snare, the same therapeutic effect can be obtained as with conventional ESD at a lower cost. The aim of this prospective, pilot, clinical feasibility study was to evaluate the safety and efficacy of ESD using the SOUTEN snare (SOUTEN-ESD). METHODS: From October 2018 to January 2019, 119 consecutive patients (121 ESD procedures, 137 colorectal neoplasms) were prospectively enrolled and treated by SOUTEN-ESD at NTT Medical Center Tokyo and Omori Red Cross Hospital. The outcomes of SOUTEN-ESD were evaluated. RESULTS: Among 137 neoplasms, SOUTEN-ESD was completed in all cases. No cases required conversion to hybrid ESD or to a dedicated ESD device. The mean procedure time was 26.1 ± 14.3 minutes. Both the en-bloc resection rate and R0 resection rate were 100%. The rate of perforation was 0%, the rate of delayed bleeding was 2.2%, and the rate of post-ESD coagulation syndrome was 2.9%. CONCLUSIONS: SOUTEN-ESD was safe and had good outcomes. Although further studies are required to examine indications for SOUTEN-ESD and confirm the results of this study, effective ESD with this novel knife is feasible. The SOUTEN snare is a realistic option for colorectal ESD. (Clinical trial registration number: UMIN 000034299.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Arimoto J, Ohata K, Chiba H, et al. Evaluation of colorectal endoscopic submucosal dissection using a multifunctional snare: a prospective clinical feasibility study (with videos). Gastrointest Endosc. 2020. PMID: 32950596. doi:10.1016/j.gie.2020.09.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。