文献速递肝病

生物电阻抗相位角评估肝硬化伴或不伴腹水患者肌少症

Phase Angle From Bioelectrical Impedance for the Assessment of Sarcopenia in Cirrhosis With or Without Ascites.
PubMed 文献 · Clin Gastroenterol Hepatol · 2020-09-02

该研究为双向性队列研究,纳入136例肝硬化患者,比较生物电阻抗分析得出的相位角(PhA)与CT骨骼肌指数(SMI)评估肌少症的表现。结果显示PhA与SMI呈中度正相关(r=0.58),诊断肌少症的AUROC为0.702,男性切点≤5.6°、女性≤5.4°,且PhA不受腹水影响,对生存的预后价值与SMI相当。

要点

  • PhA与SMI呈中度正相关(r=0.58,P<.001),且不受腹水影响。
  • 诊断肌少症的最佳PhA切点:男性≤5.6°,女性≤5.4°。
  • 在多变量分析中PhA仍与死亡率独立相关,预后准确性与SMI相当。

核心结论

  • PhA与SMI在识别肝硬化患者肌少症方面呈中度相关。
  • PhA的预后准确性(prognostic accuracy)与SMI相当,且不受腹水影响。

研究设计与样本

  • 双向性队列研究,连续纳入136例有腹部CT影像的肝硬化患者,在CT后2周内进行单频生物电阻抗分析。

主要发现

  • SMI与PhA呈正相关(r=0.58,P<.001),无论是否存在腹水。
  • PhA诊断肌少症在全人群的AUROC为0.702(男性0.748,女性0.677);最佳切点为男性≤5.6°、女性≤5.4°。
  • Kaplan-Meier曲线显示SMI和PhA均与生存显著相关。
  • 多变量分析中SMI被年龄和MELD超越,而PhA仍与死亡率独立相关。
  • 将移植视为竞争风险时,回归分析显示SMI和PhA均为死亡的独立预测因子(sHR:0.95 [0.90-0.99]和sHR:0.61 [0.42-0.88])。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Skeletal muscle index (SMI) from computed tomography (CT) reliably assesses sarcopenia, however, it is expensive and involves serial radiation exposure. Phase angle (PhA) from bioimpedance analysis (BIA) is a noninvasive, low cost, bedside nutritional tool used to monitor changes to nutritional interventions. We aimed to compare the performance of PhA with SMI to assess sarcopenia in cirrhosis. METHODS: Ambispective cohort study. Consecutive patients with cirrhosis and available images from abdominal CT scan were included. Monofrequency BIA was performed within 2 weeks CT. Spearman's correlation, ROC curve, and survival analysis with Kaplan-Meier, Cox and competing-risk regression were performed. RESULTS: 136 patients were included with a mean age of 54.5 years (60% female). Most had decompensated disease (66%) with ascites in 47%, and a mean MELD of 14 ± 6. We found positive correlations between SMI and PhA (r = 0.58 , P < .001), irrespective of the presence of ascites. The AUROC of PhA-sarcopenia in all patients was 0.702; (0.748 in males,0.677 in females). The best cutoffs of PhA for diagnosing sarcopenia were ≤5.6° in males and ≤5.4° in females. SMI and PhA were significantly associated with survival in Kaplan-Meier curves. In multivariable analyses, SMI was outperformed by age and MELD, whereas PhA remained independently associated with mortality. Considering transplantation as a competing risk, regression analysis showed both SMI and PhA to be independent predictors of mortality (sHR:0.95 [0.90-0.99] and sHR:0.61 [0.42-0.88]). CONCLUSION: PhA moderately correlates with SMI for the identification of sarcopenia in patients with cirrhosis. However, its prognostic accuracy is comparable to that of SMI, and it is not influenced by ascites.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Ruiz-Margáin A, Xie JJ, Román-Calleja BM, et al. Phase Angle From Bioelectrical Impedance for the Assessment of Sarcopenia in Cirrhosis With or Without Ascites. Clin Gastroenterol Hepatol. 2020. PMID: 32890753. doi:10.1016/j.cgh.2020.08.066

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。