仅用白光内镜预测结直肠癌浸润深度的计算机辅助诊断系统
本研究从1035个连续结直肠病变中提取3442张白光非放大非染色图像,用2751张开发计算机辅助诊断(CAD)系统,691张作为测试集,评估其区分内镜可治疗与不可治疗病变的能力,并与2名受训医师和2名专家比较。CAD系统敏感度96.7%、特异度75.0%、准确率90.3%,显著高于受训医师(92.1%、67.6%、84.9%,P均<.01),与专家相当(96.5%、72.5%、89.4%);受训医师在CAD辅助下诊断能力与专家相当。
要点
- CAD系统仅用白光非放大非染色内镜图像区分结直肠病变内镜可治疗与不可治疗。
- CAD系统敏感度96.7%、特异度75.0%、准确率90.3%,显著高于受训医师。
- CAD系统诊断能力与专家相当,受训医师在CAD辅助下达到专家水平。
核心结论
- CAD系统对结直肠病变治疗决策具有良好的诊断能力。
- 该系统可能仅用白光内镜实现更便捷、更准确的诊断。
研究设计与样本
- 从1035个连续结直肠病变提取3442张白光、非放大、非染色图像。
- 病变包括105个低级别上皮内瘤变、377个高级别上皮内瘤变、107个黏膜下浸润<1000μm的结直肠癌、146个黏膜下浸润≥1000μm的结直肠癌和300个进展期结直肠癌。
- 用2751张图像开发CAD系统,其余691张图像作为测试集评估。
- 比较CAD系统与2名受训医师和2名专家区分内镜可治疗与不可治疗病变的能力。
主要发现
- CAD系统区分内镜可治疗与不可治疗病变的敏感度为96.7%、特异度为75.0%、准确率为90.3%。
- 受训医师的敏感度为92.1%、特异度为67.6%、准确率为84.9%,CAD系统三项均显著更高(P均<.01)。
- 专家的敏感度为96.5%、特异度为72.5%、准确率为89.4%,CAD系统与之相当。
- 受训医师在CAD系统辅助下诊断能力与专家相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Endoscopic treatment is recommended for low-grade dysplasia (LGD), high-grade dysplasia (HGD), and colorectal cancer (CRC) with submucosal (SM) invasion <1000 μm. However, diagnosis of invasion depth requires experience and is often difficult. This study developed and evaluated a novel computer-aided diagnosis (CAD) system to determine whether endoscopic treatment is appropriate for colorectal lesions using only white-light endoscopy (WLE). METHODS: We extracted 3442 images from 1035 consecutive colorectal lesions (105 LGDs, 377 HGDs, 107 CRCs with SM <1000 μm, 146 CRCs with SM ≥1000 μm, and 300 advanced CRCs). All images were WLE, nonmagnified, and nonstained. We developed a novel CAD system using 2751 images; the remaining 691 images were evaluated by the CAD system as a test set. The capability of the CAD system to distinguish endoscopically treatable lesions and untreatable lesions was assessed and compared with the results from 2 trainees and 2 experts. RESULTS: The CAD system distinguished endoscopically treatable from untreatable lesions with 96.7% sensitivity, 75.0% specificity, and 90.3% accuracy. These values were significantly higher than those from trainees (92.1%, 67.6%, and 84.9%; P < .01, <.01, and <.01, respectively) and were comparable with those from experts (96.5%, 72.5%, and 89.4%, respectively). Trainees assisted by the CAD system demonstrated a diagnostic capability comparable with that of experts. CONCLUSIONS: The CAD system had good diagnostic capability for making treatment decisions for colorectal lesions. This system may enable a more convenient and accurate diagnosis using only WLE.
引用
- Tokunaga M, Matsumura T, Nankinzan R, et al. Computer-aided diagnosis system using only white-light endoscopy for the prediction of invasion depth in colorectal cancer. Gastrointest Endosc. 2020. PMID: 32735946. doi:10.1016/j.gie.2020.07.053
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。