文献速递消化内镜

新型可硬化外套管用于结肠镜稳定与防袢(附视频)

Novel rigidizing overtube for colonoscope stabilization and loop prevention (with video).
PubMed 文献 · Gastrointest Endosc · 2020-07-30

本文报告29例患者使用新型可硬化外套管(Pathfinder)辅助结肠镜及其他内镜操作的初步经验,该外套管长85 cm,抽真空后硬度增加15倍,用于结肠镜不完全、进镜深度不足或稳定性差等情况,未发生不良事件,提示该工具可能有助于减少袢形成。

要点

  • 可硬化外套管长85 cm,抽真空后硬度增加15倍,可容纳儿童结肠镜。
  • 29例中结肠镜24例(82.8%)、小肠镜4例(13.8%)、上消化道内镜1例(3.4%)。
  • 用于结肠镜不完全12例(41.4%)、进镜深度6例(20.7%)、稳定性11例(37.9%),无不良事件。

核心结论

  • 新型可硬化外套管的初步经验提示,该工具可能对受袢形成影响的结肠镜及其他内镜操作有用。

研究设计与样本

  • 病例系列,描述29例患者使用Pathfinder可硬化外套管的初步经验。

主要发现

  • 患者以男性为主(18例,62.1%),中位年龄66岁(四分位距57-72)。
  • 操作类型:上消化道内镜1例(3.4%)、结肠镜24例(82.8%)、小肠镜4例(13.8%)。
  • 外套管使用指征:结肠镜不完全12例(41.4%)、进镜深度6例(20.7%)、稳定性11例(37.9%)。
  • 下消化道内镜中位盲肠插管时间5分钟(四分位距4.25-7)。
  • 无不良事件。

关键数值与推荐

  • 外套管长85 cm,天然状态极柔软,抽真空后硬度增加15倍。
  • 外套管推进至目标位置后,内镜可经外套管推进而不在其覆盖区域形成袢。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Loop formation can impede endoscope advancement, destabilize the tip, and cause pain. Strategies to mitigate looping include torque-based reduction maneuvers, variable stiffness shafts, and abdominal splinting. In some cases, these strategies are insufficient, and there is need for novel instruments. Loop formation is of particular concern in colonoscopy, but it can also impact performance of other endoscopic procedures such as enteroscopy and altered-anatomy ERCP. In this case series we demonstrate the utility of a novel rigidizing overtube (Pathfinder; Neptune Medical, Burlingame, Calif, USA) in colonoscopy and other endoscopic procedures where loop management is critical. METHODS: We describe our initial experience with the Pathfinder overtube in 29 patients. The overtube is 85 cm long and can accommodate a pediatric colonoscope. In its native state, the overtube is extremely flexible. Once the overtube is advanced to the desired location, application of a vacuum to the device causes the device to become 15 times stiffer. The endoscope can then be advanced through the overtube without loop formation in the region that the overtube traverses. RESULTS: The overtube was used in 29 patients to assist with difficult procedures. Patients were predominantly men (n = 18; 62.1%), with a median age of 66 years (interquartile range, 57-72). One patient received an upper endoscopy (3.4%), 24 received colonoscopy (82.8%), and 4 received enteroscopy (13.8%). The overtube was used in 12 procedures for incomplete colonoscopy (41.4%), 6 for depth (20.7%), and 11 for stability (37.9%). Colonoscopy was performed in the setting of screening (n = 3), surveillance given polyp history (n = 7), referrals for polyp removal (n = 10), workup of iron deficiency anemia (n = 2), and incomplete colonoscopy (n = 1). The lower endoscopy cases had a median cecal intubation time of 5 minutes (interquartile range, 4.25-7). Enteroscopy was performed in 4 patients: In one patient the distal 60 cm of the ileum was examined with a pediatric colonoscope to exclude ileitis, in another the overtube was used to stabilize a 6-mm endoscope to traverse a tight Crohn's ileocolonic stricture, in a third patient altered-anatomy ERCP was performed using an enteroscope through the overtube to reach a hepaticojejunostomy, and in the final patient upper enteroscopy was performed and the mid-jejunum was reached. We present 4 cases that demonstrate the use of the overtube. There were no adverse events. CONCLUSIONS: Initial experience with a novel rigidizing overtube suggests that this tool can be useful in colonoscopy and other endoscopic procedures affected by looping.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Wei MT, Hwang JH, Watson RR, et al. Novel rigidizing overtube for colonoscope stabilization and loop prevention (with video). Gastrointest Endosc. 2020. PMID: 32739483. doi:10.1016/j.gie.2020.07.054

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。