文献速递消化内镜消化道出血

一种新型图像增强技术在內镜黏膜下剥离术中实现止血的效果

Efficacy of a new image-enhancement technique for achieving hemostasis in endoscopic submucosal dissection.
PubMed 文献 · Gastrointest Endosc · 2020-06-01

研究评估双红光成像(DRI)在內镜黏膜下剥离术(ESD)中识别出血点并缩短止血时间的效用,对97例患者378次出血事件交替使用DRI与白光成像(WLI)管理,并用眼动追踪比较4名内镜医师识别出血点的眼动距离;结果显示DRI组平均止血时间显著更短,所有内镜医师在DRI组的平均眼动距离均显著短于WLI组。

要点

  • DRI组平均止血时间显著短于WLI组。
  • 所有内镜医师在DRI组的平均眼动距离均显著短于WLI组。
  • DRI有助于清晰识别出血点并促进ESD中的止血。

核心结论

  • DRI可提供有用的图像,帮助清晰识别出血点并促进ESD中的止血。
  • DRI是可行的,可能有助于比WLI更安全、更快速地成功完成ESD。

研究设计与样本

  • 对97例接受ESD患者的378次出血事件交替使用DRI与WLI进行管理,并测量每次止血事件的止血时间。
  • 使用便携式眼动追踪眼镜,向4名经验丰富的内镜医师展示ESD术中出血的随机视频(WLI和DRI各20例),识别每个视频中的出血点,并比较WLI组与DRI组每单位时间内直至识别出血点的平均眼动距离。

主要发现

  • DRI组平均止血时间显著更短。
  • 所有内镜医师在DRI组的平均眼动距离均显著短于WLI组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Hemostasis during endoscopic submucosal dissection (ESD) can sometimes be challenging and stressful for the endoscopist. Therefore, we aimed to assess the usefulness of dual red imaging (DRI), a new image enhancement technique that uses 3 wavelengths (540, 600, and 630 nm) to visualize bleeding points and to examine the efficacy of DRI in shortening the time required to achieve hemostasis (hemostasis time) during ESD. METHODS: DRI and white-light imaging (WLI) were used alternately for managing 378 bleeding events in 97 patients undergoing ESD. Hemostasis time for each hemostasis event was measured. Using portable eye-tracking glasses, 4 experienced endoscopists were shown random videos of intraoperative bleeding during ESD (20 cases each on WLI and DRI) and identified the bleeding point in each video. The mean distances of eye movement per unit of time until the bleeding point were identified in each video and compared between the WLI and DRI groups. RESULTS: Average hemostasis time was significantly shorter in the DRI group. The mean distance of eye movement was significantly shorter in the DRI group than in the WLI group for all endoscopists. CONCLUSIONS: DRI can offer useful images to help in clearly detecting bleeding points and in facilitating hemostasis during ESD. It is feasible and may help in successfully performing ESD that is safer and faster than WLI. (Clinical trial registration number: UMIN000018309.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Maehata T, Fujimoto A, Uraoka T, et al. Efficacy of a new image-enhancement technique for achieving hemostasis in endoscopic submucosal dissection. Gastrointest Endosc. 2020. PMID: 32497538. doi:10.1016/j.gie.2020.05.033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。