计算机辅助诊断系统在放大内镜窄带成像视频中诊断早期胃癌的性能(附视频)
本研究旨在明确计算机辅助诊断(CAD)系统与专家内镜医师在放大内镜窄带成像(ME-NBI)下诊断早期胃癌(EGC)的性能差异。CAD系统使用1492张癌性图像和1078张非癌性图像进行预训练,并在174段视频(87段癌性、87段非癌性)上评估,比较CAD系统与11位专家的AUC、准确性、敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。CAD系统总体性能良好,与部分专家相当或更优,可能有助于临床实践中的EGC诊断。
要点
- CAD系统诊断EGC的AUC为0.8684,准确性85.1%,敏感性87.4%,特异性82.8%。
- CAD系统准确性显著高于2位专家,显著低于1位专家,与其余8位专家无显著差异。
- CAD系统在ME-NBI视频诊断EGC中总体性能良好,可能有助于临床实践。
核心结论
- CAD系统使用ME-NBI视频诊断EGC的总体性能良好,与部分专家相当或更优,可能有助于临床实践中的EGC诊断。
研究设计与样本
- CAD系统使用1492张癌性图像和1078张非癌性图像进行预训练,并在174段视频(87段癌性、87段非癌性)上评估诊断性能。
- 比较CAD系统与11位在本院使用ME-NBI诊断EGC经验超过1年的专家内镜医师。
主要发现
- CAD系统诊断EGC的AUC为0.8684。
- CAD系统准确性85.1%(95%CI 79.0-89.6),敏感性87.4%(95%CI 78.8-92.8),特异性82.8%(95%CI 73.5-89.3),PPV 83.5%(95%CI 74.6-89.7),NPV 86.7%(95%CI 77.8-92.4)。
- CAD系统准确性显著高于2位专家,显著低于1位专家,与其余8位专家无显著差异。
临床怎么用
- 作者认为CAD系统可能有助于临床实践中的EGC诊断。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: The performance of magnifying endoscopy with narrow-band imaging (ME-NBI) using a computer-aided diagnosis (CAD) system in diagnosing early gastric cancer (EGC) is unclear. Here, we aimed to clarify the differences in the diagnostic performance between expert endoscopists and the CAD system using ME-NBI. METHODS: The CAD system was pretrained using 1492 cancerous and 1078 noncancerous images obtained using ME-NBI. One hundred seventy-four videos (87 cancerous and 87 noncancerous videos) were used to evaluate the diagnostic performance of the CAD system using the area under the curve (AUC), accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). For each item, comparisons were made between the CAD system and 11 experts who were skilled in diagnosing EGC using ME-NBI with clinical experience of more than 1 year at our hospital. RESULTS: The CAD system demonstrated an AUC of 0.8684. The accuracy, sensitivity, specificity, PPV, and NPV were 85.1% (95% confidence interval [95% CI], 79.0-89.6), 87.4% (95% CI, 78.8-92.8), 82.8% (95% CI, 73.5-89.3), 83.5% (95% CI, 74.6-89.7), and 86.7% (95% CI, 77.8-92.4), respectively. The CAD system was significantly more accurate than 2 experts, significantly less accurate than 1 expert, and not significantly different from the remaining 8 experts. CONCLUSIONS: The overall performance of the CAD system using ME-NBI videos in diagnosing EGC was considered good and was equivalent to or better than that of several experts. The CAD system may prove useful in the diagnosis of EGC in clinical practice.
引用
- Horiuchi Y, Hirasawa T, Ishizuka N, et al. Performance of a computer-aided diagnosis system in diagnosing early gastric cancer using magnifying endoscopy videos with narrow-band imaging (with videos). Gastrointest Endosc. 2020. PMID: 32422155. doi:10.1016/j.gie.2020.04.079