文献速递消化道肿瘤与早癌消化内镜

二次内镜检查对结直肠癌内镜切除后残留癌检测价值低

Low value of second-look endoscopy for detecting residual colorectal cancer after endoscopic removal.
PubMed 文献 · Gastrointest Endosc · 2020-02-25

BACKGROUND AND AIMS: Endoscopic resection is often feasible for submucosal invasive colorectal cancers (T1 CRCs) and usually judged as complete.…

要点

  • 二次内镜活检对残留壁内癌灵敏度仅28%,阴性不能排除残留。
  • 活检结果不应作为是否行辅助切除的决策依据。
  • 残留壁内癌实际发生率低(6.8%),但活检价值有限。

核心结论

  • 二次内镜活检对结直肠癌内镜切除后残留壁内癌的灵敏度低,不应据此决定是否行辅助切除。

主要发现

  • 共行64例辅助外科切除和39例局部全层切除。
  • 7例(6.8%)发现残留壁内癌,其中2例二次活检阳性,灵敏度28%(95%CI<58%)。

关键数值与推荐

  • 二次内镜活检诊断残留壁内癌的灵敏度为28%(95%CI<58%)。

临床怎么用

  • 对于T1期结直肠癌内镜切除后切缘不明确但无淋巴结转移危险因素者,不应依赖二次内镜活检决定是否辅助手术。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Endoscopic resection is often feasible for submucosal invasive colorectal cancers (T1 CRCs) and usually judged as complete. If histology casts doubt on the radicality of resection margins, adjuvant surgical resection is advised, although residual intramural cancer is found in only 5% to 15% of patients. We assessed the sensitivity of biopsy specimens from the resection area for residual intramural cancer as a potential tool to estimate the preoperative risk of residual intramural cancer in patients without risk factors for lymph node metastasis (LNM). METHODS: In this multicenter prospective cohort study, patients with complete endoscopic resection of T1 CRC, scheduled for adjuvant resection due to pathologically unclear resection margins, but absent risk factors for LNM, were asked to consent to second-look endoscopy with biopsies. The results were compared with the pathology results of the surgical resection specimen (criterion standard). RESULTS: One hundred three patients were included. In total, 85% of resected lesions were unexpectedly malignant, and 45% were removed using a piecemeal resection technique. Sixty-four adjuvant surgical resections and 39 local full-thickness resections were performed. Residual intramural cancer was found in 7 patients (6.8%). Two of these patients had cancer in second-look biopsy specimens, resulting in a sensitivity of 28% (95% confidence interval, <58%). The preoperative risk of residual intramural cancer in the case of negative biopsy specimens was not significantly reduced (P = .61). CONCLUSIONS: The sensitivity of second-look endoscopy with biopsies for residual intramural cancer after endoscopic resection of CRC is low. Therefore, it should not be used in the decision whether or not to perform adjuvant resection. (Clinical trial registration number: NCT02328664.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Gijsbers KM, Post Z, Schrauwen RWM, et al. Low value of second-look endoscopy for detecting residual colorectal cancer after endoscopic removal. Gastrointest Endosc. 2020. PMID: 32105713. doi:10.1016/j.gie.2020.01.056