文献速递消化内镜消化道肿瘤与早癌

双环夹技术无黏合剂缝合结肠ESD后溃疡的可行性

Feasibility of a new ligation using the double-loop clips technique without an adhesive agent for ulceration after endoscopic submucosal dissection of the colon (with video).
PubMed 文献 · Gastrointest Endosc · 2020-02-20

这项回顾性研究纳入26例结肠ESD后使用双环夹技术缝合溃疡的患者,完全缝合率88.5%,排除腹膜反折以下直肠病变后达95.5%,仅1例迟发性术后凝血综合征,提示该技术可行,但直肠下段病变需其他方法。

要点

  • 双环夹无黏合剂缝合结肠ESD后溃疡完全缝合率88.5%。
  • 排除腹膜反折以下直肠病变后完全缝合率升至95.5%。
  • 下直肠瓣/肛缘区域病变不完全缝合显著更常见(P=.0269)。

核心结论

  • 双环夹技术无黏合剂缝合结肠ESD后溃疡是可行的。
  • 对于腹膜反折以下直肠病变,可能需要其他缝合技术。

研究设计与样本

  • 回顾性研究,纳入2019年4月至9月在Kushiro Rosai Hospital接受结肠ESD的35例患者中26例使用双环夹技术缝合ESD后溃疡床者。
  • 抗血栓药物续用或停用依据《接受抗血栓治疗患者消化内镜检查指南》。

主要发现

  • 整块R0切除率为97.1%。
  • 切除标本中位长度为3.2 cm(IQR 2.8-3.8 cm)。
  • 完全缝合率为88.5%(23/26)。
  • 排除腹膜反折以下直肠病变患者后,完全缝合率为95.5%(21/22)。
  • 缝合操作中位时间为20分钟(IQR 16-24分钟)。

临床怎么用

  • 双环夹无黏合剂技术可作为结肠ESD后溃疡缝合的可行选择。
  • 对腹膜反折以下直肠病变,应考虑其他缝合技术。

局限性

  • 回顾性研究,样本量有限(26例)。
  • 单中心研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Several ligation techniques for ulceration after endoscopic submucosal dissection (ESD) have been reported, but none have been established for clinical use because of technical complexity and the need for expensive equipment. Therefore, the technical feasibility of a new ligation method using the double-loop clips (D-L clips) technique without an adhesive agent for ulceration after ESD of the colon was assessed. METHODS: Among 35 patients who underwent ESD of the colon in Kushiro Rosai Hospital between April 2019 and September 2019, 26 patients who underwent ligation using the D-L clips technique for the post-ESD ulcer bed were included in this retrospective study. Continuation or cessation of antithrombotic agents was based on the Guidelines for Gastroenterological Endoscopy in Patients Undergoing Antithrombotic Treatment. RESULTS: The rate of en bloc R0 resection was 97.1%, the median length of the resected specimen was 3.2 cm (interquartile range [IQR], 2.8-3.8 cm), and the complete ligation rate was 88.5% (23 of 26). Excluding patients with lesion sites in the rectum below the peritoneal reflection, the complete ligation rate was 95.5% (21 of 22). The median duration of the ligation procedure was 20 minutes (IQR, 16-24 minutes). The only delayed procedural adverse event was post-ESD coagulation syndrome in 1 patient. Incomplete ligation was significantly more frequent in patients with lesion sites in the inferior rectal valve/anal verge area (P = .0269). CONCLUSIONS: Ligation using the D-L clips technique without an adhesive agent is feasible for closing ulceration after ESD of the colon, whereas other techniques may be necessary for lesions in the rectum below the peritoneal reflection.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Abiko S, Yoshida S, Yoshikawa A, et al. Feasibility of a new ligation using the double-loop clips technique without an adhesive agent for ulceration after endoscopic submucosal dissection of the colon (with video). Gastrointest Endosc. 2020. PMID: 32087192. doi:10.1016/j.gie.2020.02.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。