快速阅读软件在维持准确性的同时缩短胶囊内镜阅读时间
这项前瞻性多中心研究纳入连续未选择的胶囊内镜病例,先按常规模式逐帧阅读,再匿名随机分配至另一中心使用 Omni Mode 阅读。结果显示 Omni Mode 平均节省 24.6 分钟(95%CI 22.8-26.9,P<.0001),阅读时间平均减少 40%,且两种模式的临床结论无显著差异。
要点
- Omni Mode 阅读胶囊内镜平均节省 24.6 分钟,阅读时间减少约 40%。
- 两种阅读模式的临床结论无显著差异。
- Omni Mode 遗漏病灶 539 个,准确率 .75;常规模式遗漏 647 个,准确率 .70。
核心结论
- 胶囊内镜使用 Omni Mode 阅读可平均缩短阅读时间 40%,且不降低临床准确性。
研究设计与样本
- 前瞻性多中心研究,覆盖 9 个欧洲中心,连续未选择的胶囊内镜病例先常规模式阅读,再匿名随机分配至另一中心用 Omni Mode 阅读。
主要发现
- 患者平均年龄 49.5 岁(范围 18-91),贫血或消化道出血检查占 71.8%,平均小肠通过时间 4 小时 26 分钟。
- 常规模式平均阅读时间 42.5 分钟,Omni Mode 显著更快(P<.0001),平均节省 24.6 分钟(95%CI 22.8-26.9)。
- 共识别 2127 个病灶,按 P 分类为 P0(1234)、P1(656)、P2(237)。
- 两种模式均识别 40%(n=936)的病灶,1186 个病灶仅由其中一种模式识别。
- 常规模式遗漏 647 个病灶,准确率 .70;Omni Mode 遗漏 539 个病灶,准确率 .75;两种模式的临床结论无显著差异。
临床怎么用
- 在维持临床准确性的前提下,Omni Mode 可显著缩短胶囊内镜阅读时间,平均节省约 24.6 分钟。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUNDS AND AIMS: A typical capsule endoscopy (CE) case generates tens of thousands of images, with abnormalities often confined to a just few frames. Omni Mode is a novel EndoCapsule software algorithm (Olympus, Tokyo, Japan) that proposes to intelligently remove duplicate images while maintaining accuracy in lesion detection. METHODS: This prospective multicenter study took place across 9 European centers. Consecutive, unselected CE cases were read conventionally in normal mode, with every captured frame reviewed. Cases were subsequently anonymized and randomly allocated to another center where they were read using Omni Mode. Detected lesions and reading times were recorded, with findings compared between both viewing modes. The clinical significance of lesions was described according to the P classification (P0, P1, and P2). Where a discrepancy in lesion detection in either mode was found, expert blinded review at a consensus meeting was undertaken. RESULTS: The patient population undergoing CE had a mean age of 49.5 years (range, 18-91), with the investigation of anemia or GI bleeding accounting for 71.8% of cases. The average small-bowel transit time was 4 hours, 26 minutes. The mean reading time in normal mode was 42.5 minutes. The use of Omni Mode was significantly faster (P < .0001), with an average time saving of 24.6 minutes (95% confidence interval, 22.8-26.9). The 2127 lesions were identified and classified according to the P classification as P0 (1234), P1 (656), and P2 (237). Lesions were identified using both reading modes in 40% (n = 936), and 1186 lesions were identified by either normal or Omni Mode alone. Normal mode interpretation was associated with 647 lesions being missed, giving an accuracy of .70. Omni Mode interpretation led to 539 lesions being missed, with an accuracy of .75. There was no significant difference in clinical conclusions made between either reading mode. CONCLUSIONS: This study shows that CE reading times can be reduced by an average of 40%, without any reduction in clinical accuracy.
引用
- Beg S, Wronska E, Araujo I, et al. Use of rapid reading software to reduce capsule endoscopy reading times while maintaining accuracy. Gastrointest Endosc. 2020. PMID: 31981645. doi:10.1016/j.gie.2020.01.026