十二指肠镜按厂商推荐清洗后培养与隔离结果
本研究评估十二指肠镜按厂商推荐高水平消毒后培养与隔离的效果。
要点
- 初次高水平消毒后18%十二指肠镜培养阳性,革兰阴性菌仅3%。
- 重复消毒对初次和重复阳性培养的清除率分别为86%和75%。
- 厂商推荐初始消毒不能完全消除细菌污染,需额外措施。
核心结论
- 按厂商推荐初始高水平消毒后18%十二指肠镜培养阳性,仅3%为革兰阴性菌。
- 重复消毒对初次和重复阳性培养的清除率分别为86%和75%。
- 初始消毒不总能消除细菌污染,需额外步骤降低感染风险。
研究设计与样本
- 单中心回顾性研究,2015年12月至2018年7月共140次十二指肠镜清洗,280份标本。
- 采用厂商推荐清洗联合CDC推荐培养与隔离,隔离至培养结果。
- 阳性定义为低关注菌>10 CFU或高关注菌任何CFU。
主要发现
- 234份初次培养标本中28份(12%)阳性,占培养十二指肠镜的18%。
- 36份第二次培养中5份(14%)阳性,8份第三次培养中2份(25%)阳性。
- 11例(8%)在最终培养结果前解除隔离,无ERCP相关感染患者。
临床怎么用
- 厂商推荐初始高水平消毒后应结合培养与隔离监测。
- 培养阳性时重复消毒,对初次和重复阳性清除率分别为86%和75%。
- 需额外措施降低十二指肠镜传播感染风险。
局限性
- 单中心研究,样本量有限。
- 11例(8%)在最终培养结果前解除隔离,可能影响观察。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Outbreaks of infections transmitted by duodenoscopes have prompted changes to duodenoscope cleaning protocols. However, little is known about effectiveness of clinical cleaning practices. We present culture data after duodenoscope manufacturer-recommended high-level disinfection (HLD) and quarantine. METHODS: Our institution adopted a combination of manufacturer-recommended cleaning with the Centers for Disease Control and Prevention-recommended culture and quarantine in 2015. Duodenoscopes (models TJF-Q180V, TJF-160, and PJF-160; Olympus, Center Valley, Penn, USA) underwent HLD according to the manufacturer's reprocessing manual protocols after use. Two culture specimens were then obtained using a sterile brush from the distal tip, including elevator mechanism, and by flushing sterile water through the working channel. Duodenoscopes were quarantined until cultures resulted. Positive cultures were defined as >10 colony-forming units (CFUs) of low-concern organisms or any CFUs of high-concern organisms according to Centers for Disease Control and Prevention recommendations. If either culture specimen was positive, the process was repeated until cultures were negative. Data were collected from December 2015 to July 2018. RESULTS: There were 140 instances of duodenoscope cleaning with 280 specimens. Twenty-eight of 234 (12%) initial culture specimens (18% of cultured duodenoscopes) were positive. Five of 36 (14%) second cultures were positive. Two of 8 (25%) third cultures were positive. Ninety-eight percent of organisms cultured were gram positive. In 8 instances both culture methods (brushing and flush) were positive; otherwise, only 1 method was positive. In 11 instances (8%) duodenoscopes were removed from quarantine before final culture results. No patient had infections related to ERCP. CONCLUSIONS: Eighteen percent of duodenoscopes had a positive culture after initial HLD. Only 3% were gram-negative bacteria. Repeated HLD was 86% and 75% effective at eliminating initial and repeat positive cultures, respectively. Initial HLD per manufacturer recommendations is not always effective at eliminating bacterial contamination. Additional steps are necessary to decrease risks of duodenoscope-transmitted infections.
引用
- Mark JA, Underberg K, Kramer RE, et al. Results of duodenoscope culture and quarantine after manufacturer-recommended cleaning process. Gastrointest Endosc. 2020. PMID: 31945325. doi:10.1016/j.gie.2019.12.050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。