文献速递消化道肿瘤与早癌消化内镜

深度学习系统在Barrett食管患者中检测肿瘤的准确性优于内镜医师:一项多步骤训练与验证的基准研究

Deep-Learning System Detects Neoplasia in Patients With Barrett's Esophagus With Higher Accuracy Than Endoscopists in a Multistep Training and Validation Study With Benchmarking.
PubMed 文献 · Gastroenterology · 2019-11-22

本研究开发并验证了一种用于实时临床实践的深度学习计算机辅助检测(CAD)系统,旨在提高Barrett食管(BE)早期肿瘤的内镜检出率。系统使用5个独立内镜数据集训练,其中494,364张标记图像用于预训练,1704张来自669例患者的食管高分辨率图像用于训练和验证。在数据集4中,CAD系统分类图像为肿瘤性或非不典型增生BE的准确性为89%、敏感性90%、特异性88%;在数据集5中,CAD系统与53名普通内镜医师相比,准确性88% vs 73%、敏感性93% vs 72%、特异性83% vs 74%。CAD系统在检测到的所有肿瘤中,其肿瘤范围描绘与BE专家重叠,并在97%和92%的病例中(数据集4和5)确定了最佳活检部位。

要点

  • CAD系统在BE早期肿瘤检测中准确性达88-89%,优于普通内镜医师的73%。
  • CAD系统敏感性达90-93%,显著高于普通内镜医师的72%。
  • CAD系统在97%和92%的病例中准确识别最佳活检部位。

核心结论

  • 深度学习CAD系统可高精度检测BE患者早期肿瘤,描绘性能接近完美,并在多数病例中确定最佳活检部位。

研究设计与样本

  • 开发混合ResNet-UNet模型CAD系统,使用5个独立内镜数据集进行训练和验证。
  • 预训练使用494,364张标记内镜图像,来自所有肠段。
  • 使用来自669例患者的1704张食管高分辨率图像(严格确认的BE早期肿瘤和非不典型增生BE)。
  • 数据集4和5用于评估系统性能,数据集5由来自4个国家的53名普通内镜医师评分以进行基准比较。

主要发现

  • 数据集4(80例患者和图像):CAD系统分类准确性89%、敏感性90%、特异性88%。
  • 数据集5(80例患者和图像):CAD系统 vs 普通内镜医师准确性88% vs 73%、敏感性93% vs 72%、特异性83% vs 74%。
  • CAD系统准确性高于53名非专家内镜医师中的任何个体,描绘性能相当。
  • CAD系统在数据集4和5中检测到的所有肿瘤的描绘区域与BE专家重叠。
  • CAD系统在数据集4和5中分别有97%和92%的病例识别出肿瘤的最佳活检部位。

临床怎么用

  • CAD系统可作为实时辅助工具,提高BE早期肿瘤的内镜检出准确性。
  • CAD系统可帮助确定最佳活检部位,指导临床活检决策。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: We aimed to develop and validate a deep-learning computer-aided detection (CAD) system, suitable for use in real time in clinical practice, to improve endoscopic detection of early neoplasia in patients with Barrett's esophagus (BE). METHODS: We developed a hybrid ResNet-UNet model CAD system using 5 independent endoscopy data sets. We performed pretraining using 494,364 labeled endoscopic images collected from all intestinal segments. Then, we used 1704 unique esophageal high-resolution images of rigorously confirmed early-stage neoplasia in BE and nondysplastic BE, derived from 669 patients. System performance was assessed by using data sets 4 and 5. Data set 5 was also scored by 53 general endoscopists with a wide range of experience from 4 countries to benchmark CAD system performance. Coupled with histopathology findings, scoring of images that contained early-stage neoplasia in data sets 2-5 were delineated in detail for neoplasm position and extent by multiple experts whose evaluations served as the ground truth for segmentation. RESULTS: The CAD system classified images as containing neoplasms or nondysplastic BE with 89% accuracy, 90% sensitivity, and 88% specificity (data set 4, 80 patients and images). In data set 5 (80 patients and images) values for the CAD system vs those of the general endoscopists were 88% vs 73% accuracy, 93% vs 72% sensitivity, and 83% vs 74% specificity. The CAD system achieved higher accuracy than any of the individual 53 nonexpert endoscopists, with comparable delineation performance. CAD delineations of the area of neoplasm overlapped with those from the BE experts in all detected neoplasia in data sets 4 and 5. The CAD system identified the optimal site for biopsy of detected neoplasia in 97% and 92% of cases (data sets 4 and 5, respectively). CONCLUSIONS: We developed, validated, and benchmarked a deep-learning computer-aided system for primary detection of neoplasia in patients with BE. The system detected neoplasia with high accuracy and near-perfect delineation performance. The Netherlands National Trials Registry, Number: NTR7072.

来源:Gastroenterology,查看原文。版权归原作者所有。

引用

  1. de Groof AJ, Struyvenberg MR, van der Putten J, et al. Deep-Learning System Detects Neoplasia in Patients With Barrett's Esophagus With Higher Accuracy Than Endoscopists in a Multistep Training and Validation Study With Benchmarking. Gastroenterology. 2019. PMID: 31759929. doi:10.1053/j.gastro.2019.11.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。